![Agilent Technologies E1468A Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/agilent-technologies/e1468a/e1468a_user-manual_2867811040.webp)
40 Relay Matrix Switch Command Reference
Chapter 3
ABORt
The ABORt command subsystem stops a scan in progress when the
scan is enabled via the interface and the trigger source is
TRIGger:SOURce BUS or TRIGger:SOURce HOLD.
Subsystem Syntax
ABORt
Comments
ABORt Actions:
ABORt stops the scan and invalidates the current
channel_list.
Stopping a Scan Enabled Via Interface:
When a scan is enabled via an
interface, an interface CLEAR command (CLEAR 7) can be used to stop
the scan. When the scan is enabled via the interface and TRIG:SOUR
BUS or HOLD is set, you can use ABORt to stop the scan.
Restarting a Scan:
Use the INIT command to restart the scan.
Related Commands:
ARM, INITiate:CONTinuous, [ROUTe:]SCAN,
TRIGger
Example
Stopping a Scan with ABORt
This example stops a (continuous) scan in progress.
TRIG:SOUR BUS
! *TRG command is trigger source
INIT:CONT ON
! Set continuous scanning
SCAN (@10000:10003)
! Scan channels 00-03
INIT
! Start scan, close channel 00
.
.
ABOR
! Abort scan in progress.
Содержание E1468A
Страница 2: ......
Страница 6: ...6 Notes...
Страница 10: ...10 Notes...
Страница 14: ...14 Getting Started Chapter 1 Figure 1 3 E1468A E1469A Connector Pin Out...
Страница 30: ...30 Getting Started Chapter 1 Notes...
Страница 68: ...68 Relay Matrix Switch Specifications Appendix A Notes...
Страница 78: ...78 Relay Matrix Switch Error Messages Appendix C Notes...
Страница 83: ...E1468 90005 Manual Part Number E1468 90005 Printed in U S A E1200...
Страница 84: ......