Using the Form C Switch 35
Chapter 2
Example:
Controlling RF
Switches/Step
Attenuators
(BASIC)
Figure 2-2 shows one way to drive the 8761 SPDT RF Switches or 33300
Series Programmable Step Attenuators. (Figure 2-2 only shows control for
the 33300 40 dB step. Additional drive relays are required for the 10 dB and
20 dB steps.)
The 8761A and 33300A/C operate from a 12V - 15V coil voltage, while the
8761B and 33300B/D operate from a 24V - 30V coil voltage. To close
channel 00, execute the following. To open channel 00, use OPEN (@100).
10 DISP "Applying -12V"
20 OUTPUT 70915; "CLOS (@100)"
!Close channel 00 relay (connect
NO to C). 1 is the card number
and 00 is the channel number.
30 END
Figure 2-1. Example: Voltage Switching
C
NO
NC
Channel
00
C0NO
C0NC
C0C
TERMINAL
MODULE
2
1
E
E
MODULE
E1463A