12 Getting Started
Chapter 1
Each channel is switched by opening or closing the appropriate channel
relay. Since the relays are nonlatching, the relays are all open during
power-up or power-down.
When a reset occurs, all channel commons (C) are connected to the
corresponding normally closed (NC) contacts. When a channel is closed,
the common contact (C) is connected to the normally open contact (NO).
User inputs and outputs to each channel are via the NO, NC, and C terminal
connectors on the terminal module.
Figure 1-1. Form C Switch Simplified Schematic
TERMINAL MODULE
C0NO
C0C
C0NC
C0N0
C0C
C0NC
NC
NO
Channel 0
E1463A MODULE
Channel 15
C15N0
C15C
C15C
NO
NC
C15NC
C15C
C15NO
Pads
for MOVS
Pads
for MOVS
Jumper
Channel 16
NO
C16C
C16C
C16N0
NC
C16NC
C16C
C16NO
Channel 31
NO
C31C
C31C
C31N0
NC
C31C
C31NC
C31NO