Agilent E1330B Digital I/O Module Command Reference
67
Chapter 5
:DIGital:FLAG
n
?
MEASure:DIGital:FLAG
n
?
reads the status of the flag line on port n and returns a
0
or
1
to show whether a peripheral has set the flag line to READY or BUSY.
Parameters
Comments
•
MEASure:DIGital:FLAG
n
?
is used to implement custom handshakes.
The handshake mode must be set to
NONE
to use these commands.
•
:FLAG
n is the keyword used for commands relating to the flag line at port n.
The port number n must be the last character of the keyword without spaces.
•
If n is omitted,
FLAG0
is used.
•
MEASure:DIGital:FLAG
n
?
may be affected by the condition of the flag
combining jumpers. Refer to Chapter 2 for additional information.
•
Related Commands:
[SOURce:]DIGital:CONTrol
n
:POLarity?
,
[SOURce:]DIGital:CONTrol
n
[:VALue]
,
[SOURce:]DIGital:FLAG
n
:POLarity
,
[SOURce:]DIGital:FLAG
n
:POLarity?
Example
MEAS:DIG:FLAG1?
reads the port 1 flag line.
Parameter Name
Parameter
Type
Range of Values
Default
FLAG
n
Numeric
none, 0, 1, 2, or 3
0
Содержание E1330B
Страница 2: ......
Страница 10: ...8 Notes ...
Страница 11: ...9 Notes ...
Страница 12: ...10 Notes ...
Страница 25: ...Configuring the Agilent E1330B Digital I O Module 23 Chapter 2 Figure 2 6 J1 and J2 Connector Pinouts ...
Страница 32: ...30 Configuring the Agilent E1330B Digital I O Chapter 2 Notes ...
Страница 42: ...40 Using the Agilent E1330B Digital I O Module Chapter 3 Notes ...
Страница 58: ...56 Understanding the Agilent E1330B Digital I O Module Chapter 4 Notes ...
Страница 104: ...102 Agilent E1330B Digital I O Module Command Reference Chapter 5 Notes ...
Страница 146: ...144 Error Messages Appendix C Notes ...