![Agilent Technologies 969-8935 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/agilent-technologies/969-8935/969-8935_user-manual_2868752066.webp)
Technical Information
RS 232/RS 485 Communication Description
17
TV 551/701 SEM Navigator User Manual / 87-900-958-01(G)
239/
276
Window-Meanings
Tab. 7
N. Read/
Write
Data
Type
Description Admitted
Values
000
R/W
L
Start/Stop (in remote
mode the window is a
read only)
Start = 1
Stop = 0
001
R/W
L
Low Speed activation
NO = 0
YES = 1
(default = 0)
008 R/W
L Remote
(default)
or
Serial configuration
Remote = 1
Serial = 0 (default = 1)
100
R/W
L
Soft Start (write only in
Stop condition)
YES = 1
NO = 0
101
R/W
N
Set Point type
0 = Frequency
1 = Current
2 = Time (default = 0)
102
R/W
N
Set Point threshold
(expressed in Hz, mA or s)
(default = 643)
103
R/W
N
Set Point delay: time
between the pump start
and the set point check
(seconds)
0 to 99999
(default = 0)
104 R/W
L Set
Point
signal
activation type: the
signal can be "high level
active" or "low level
active"
0 = high level active
1 = low level active
(default = 0)
105
R/W
N
Set point hysteresis (in
% of threshold)
0 to 100 (default = 2)
106
R/W
L
Water cooling
0 = NO
1 = YES
107
R/W
L
Active Stop
0 = NO
Содержание 969-8935