![Agilent Technologies 8712ES Скачать руководство пользователя страница 294](http://html.mh-extra.com/html/agilent-technologies/8712es/8712es_programmers-manual_2867956294.webp)
Programmer’s Guide
13-5
SCPI Error Messages
Command Errors
−
112
Program mnemonic too long — The header contains more that twelve
characters.
−
113
Undefined header — The header is syntactically correct, but it is undefined
for this specific device; for example,
*XYZ
is not defined for any device.
−
114
Header suffix out of range — The value of a numeric suffix attached to a
program mnemonic makes the header invalid.
−
120
Numeric data error — This error, as well as errors
−
121 through
−
129, are
generated when parsing a data element which appears to be numeric,
including the nondecimal numeric types. This particular error message
should be used if the device cannot detect a more specific error.
−
121
Invalid character in number — An invalid character for the data type being
parsed was encountered; for example, an alpha in a decimal numeric or a
"9" in octal data.
−
123
Exponent too large — The magnitude of the exponent was larger than
32000.
−
124
Too many digits — The mantissa of a decimal numeric data element
contained more than 255 digits excluding leading zeros.
−
128
Numeric data not allowed — A legal numeric data element was received,
but the device does not accept one in this position for the header.
−
130
Suffix error — This error, as well as errors
−
131 through
−
139, are
generated when parsing a suffix. This particular error message should be
used if the device cannot detect a more specific error.
−
131
Invalid suffix — The suffix does not follow the correct syntax, or the suffix is
inappropriate for this device.
−
134
Suffix too long — The suffix contained more than 12 characters.
−
138
Suffix not allowed — A suffix was encountered after a numeric element
which does not allow suffixes.
−
140
Character data error — This error, as well as errors
−
141 through
−
149, are
generated when parsing a character data element. This particular error
message should be used if the device cannot detect a more specific error.
Error
Number
Error Description
Содержание 8712ES
Страница 11: ...1 1 1 Introduction to GPIB Programming ...
Страница 27: ...2 1 2 Synchronizing the Analyzer and a Controller ...
Страница 36: ...3 1 3 Passing Control ...
Страница 39: ...4 1 4 Data Types and Encoding ...
Страница 46: ...5 1 5 Using Status Registers ...
Страница 71: ...6 1 6 Trace Data Transfers ...
Страница 98: ...6 28 Programmer sGuide Trace Data Transfers Internal Measurement Arrays ...
Страница 99: ...7 1 7 Using Graphics ...
Страница 105: ...8 1 8 Front Panel Keycodes ...
Страница 111: ...9 1 9 Introduction to SCPI ...
Страница 129: ...10 1 10 Menu Map with SCPI Commands ...
Страница 268: ...12 1 12 SCPI Conformance Information ...
Страница 290: ...13 1 13 SCPI Error Messages ...