Installing ParBERT 43/45G Systems
7 Special ParBERT Systems
Agilent 81250 ParBERT Installation Guide, May 2004
7-7
analyzing digital signals as with any Agilent 81250 Parallel Bit Error
Ratio Tester.
For example, if you wish to stimulate a multipler device, you will have to
disconnect the generators from the MUX module.
To use a ParBERT 43/45G pattern generator or error detector system for
general purposes:
1 Disconnect all signal cables from the frontends.
It is strongly recommended to unscrew the cables from the
generator/analyzer modules and to leave the connectors at the
MUX/DEMUX module in place, because the cables have been
calibrated. If you disconnect both sides, you should label the cables so
that they can be re-installed for the same connections.
2 Remove the MUX/DEMUX module from the mainframe.
As long as the MUX/DEMUX module is installed, the software will not
allow you to access the channel parameters.
Take ESD precautions, e. g. wear a grounded wrist strap. These modules
are susceptible to electrostatic discharge.
3 After power on, run the Agilent 81250 Configuration tool and activate
the “
Build Systems
” function.
After that, you have a normal, general-purpose ParBERT system with 16
generator or analyzer channels that can be used for stimulating a
multiplexer or measuring the output of a demultiplexer device. You can
align the connectors, attach your test cables, and compensate for cable
and propagation delays.
ParBERT 45G to ParBERT conversion
CAUTION
Содержание 81250
Страница 1: ...Agilent Parallel Bit Error Ratio Tester 81250 ParBERT Installation Guide Agilent Technologies ...
Страница 12: ...1 About this Manual Document History 1 6 Agilent 81250 ParBERT Installation Guide May 2004 ...
Страница 30: ...2 Introduction Unpacking ParBERT 2 18 Agilent 81250 ParBERT Installation Guide May 2004 ...
Страница 138: ...Appendix Declaration of Conformity 10 2 Agilent 81250 ParBERT Installation Guide May 2004 Declaration of Conformity ...
Страница 139: ...Declaration of Conformity Appendix Agilent 81250 ParBERT Installation Guide May 2004 10 3 ...
Страница 141: ...Site Attenuation Requirements Appendix Agilent 81250 ParBERT Installation Guide May 2004 10 5 ...
Страница 142: ...Appendix Site Attenuation Requirements 10 6 Agilent 81250 ParBERT Installation Guide May 2004 ...
Страница 145: ......
Страница 146: ...Copyright Agilent Technologies 2004 Printed in Germany May 2004 81250 91010 Agilent Technologies ...