![Agilent Technologies 4352B Скачать руководство пользователя страница 279](http://html.mh-extra.com/html/agilent-technologies/4352b/4352b_service-manual_2867893279.webp)
Error
Messages
(Alphabetical
Order)
44
F-V
Input
Overow
The
input
frequency
to
the
4352B 's
F-V
converter
is
too
high.
This
message
indicates
that
the
DUT's
frequency
has
uctuated
widely
in
a
very
short
time
(several
hundred
kHz
in
several
tens
of
ms).
V
erify
the
DUT's
output
frequency
stability
.
0257
FILE
NAME
ERROR
Indicates
that
a
legal
program
command
or
query
could
not
be
executed
because
the
le
name
on
the
device
media
was
in
error
.
F
or
example
,
an
attempt
was
made
to
copy
to
a
duplicate
le
name
.
The
denition
of
what
constitutes
a
le
name
error
is
device-specic
.
53
FM
Deviation
Range
Overload
The
DUT's
FM
deviation
is
out
of
the
measurement
range
.
Press
4
Sense
Range
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
FM
DEV
RANGE
,
and
select
a
measurement
range
larger
than
the
current
setting.
(FM
deviations
over
200
kHz
cannot
be
measured.)
43
F-V
Input
Underow
The
input
frequency
to
the
4352B 's
F-V
converter
is
too
low
.
This
message
indicates
that
the
DUT's
frequency
has
uctuated
widely
in
a
very
short
time
(several
hundred
kHz
in
several
tens
of
ms).
V
erify
the
DUT's
output
frequency
stability
.
0105
GET
not
allowed
A
Group
Execute
Trigger
(GET)
was
received
within
a
program
message
(see
IEEE
488.2,
7.7).
0240
Hardware
error
Indicates
that
a
legal
program
command
or
query
could
not
be
executed
because
of
a
hardware
problem
in
the
4352B.
Denition
of
what
constitutes
a
hardware
problem
is
device-specic
.
This
error
message
might
be
displayed
if
the
4352B
detects
an
unknown
problem
related
to
errors
0241
through
0249.
0241
Hardware
missing
A
legal
program
command
or
query
could
not
be
executed
because
of
missing
4352B
hardware
.
F
or
example
,
an
option
was
not
installed.
0111
Header
separator
error
A
character
that
is
not
a
legal
header
separator
was
encountered
while
parsing
the
header
.
F
or
example
,
no
white
space
followed
the
header
,
thus
*SRE4
is
an
error
.
0114
Header
Sux
out
of
range
The
value
of
a
numeric
sux
attached
to
a
program
mnemonic
makes
the
header
invalid.
0224
Illegal
parameter
value
Used
where
an
exact
value
,
from
a
list
of
possibilities
,
was
expected.
Messages-6
Содержание 4352B
Страница 11: ......
Страница 31: ......
Страница 73: ......
Страница 80: ...Figure 3 4 List Box Menu Adjustments and Correction Constants 3 7 ...
Страница 82: ...Figure 3 6 Reference Frequency Adjustment Location Adjustments and Correction Constants 3 9 ...
Страница 85: ...Figure 3 9 Third IF AMP GAIN Adjustment Location 3 12 Adjustments and Correction Constants ...
Страница 103: ...Figure 4 1 Troubleshooting Organization 4 2 Overall T roubleshooting ...
Страница 113: ......
Страница 130: ...Figure 5 11 Power Supply Block Diagram 1 Power Supply T roubleshooting 5 17 ...
Страница 131: ...Figure 5 12 Power Supply Block Diagram 2 5 18 Power Supply T roubleshooting ...
Страница 132: ...Figure 5 13 Power Supply Block Diagram 3 Power Supply T roubleshooting 5 19 ...
Страница 133: ......
Страница 135: ...Figure 6 1 Digital Control Group Simpli ed Block Diagram 6 2 Digital Control T roubleshooting ...
Страница 146: ...Figure 7 2 Source Group Troubleshooting Flow Source Group T roubleshooting 7 3 ...
Страница 154: ...Figure 8 2 Receiver Group Troubleshooting Flow Receiver Group T roubleshooting 8 3 ...
Страница 198: ...Figure 10 1 Power Supply Functional Group Simpli ed Block Diagram Theory of Operation 10 3 ...
Страница 203: ...Figure 10 3 Digital Control Group Simpli ed Block Diagram 10 8 Theory of Operation ...
Страница 269: ......
Страница 272: ...Figure B 1 Power Cable Supplied Power Requirement B 3 ...
Страница 273: ......
Страница 293: ...Error Messages Numerical Order 0400 Query error 0410 Query INTERRUPTED 0420 Query UNTERMINATED Messages 20 ...