I - 14
Installation
The doorphone relays of the AS 1x, 2x and 3x can be used to operate connected doorphones
or use the relays to switch other applications such as an additional bell or lighting.
Via
programming
the relay will be set to operate as a pulse relay (3 seconds on then off
when activated) or on/off relay. The relays can be switched from every extension phone or
any external phone. In addition an extension number can be allocated to a relay which is
then entered in the call distribution table to activate additional equipment if so required.
The relay contacts have a spark absorbing circuit of 1 kOhm, and a bridged 100nF
Capacitor. Max load 30 VDC / 1A or 125 VAC / 0,5 A resistance load only
Doorphone-Relays
You may connect senors to the AS 3x which have normally closed or normally open
contacts. Power for sensors can also be supplied via the telephone system. Max 12 V and
200 mA. Due to differential inputs you may connect a mixture of contacts. (Connection see
illustration) The last contact must be terminated with a 12,1 k Ohm Resistor. (Included in
pack).
Alternatively you may trigger these circuits like bell push contacts. Please note that the
type of connection will be not be changed. (with termination resistor)
Sensor Inputs AS 3x
Relay
You may use the relays of the AS3x to switch other equipment on or off.
Via
programming
the relay will be set to operate as a pulse relay (3 seconds on then off
when activated) or on/off relay. The relays can be switched from every extension phone or
any external phone. In addition an extension number can be allocated to a relay which is
then entered in the call distribution table to activate additional equipment if so required.
The relay contacts have a spark absorbing circuit of 1 kOhm, and a bridged 100nF
Capacitor. Max load 30 VDC / 1A or 125 VAC / 0,5 A resistance load only
1-In
A-Gnd
12,1 kOhm
Termination Resistor
Содержание AS 1x
Страница 1: ...Manual Business Line AS 1x 2x 3x ISDN PBX System...
Страница 11: ...E 11 Introduction...
Страница 32: ...1 2 System Telephones ST 25 DECT 30 ST 30...
Страница 131: ...1 101 System Telephones ST 25 DECT 30 ST 30...
Страница 132: ...2 2 Analogue and ISDN Phones...
Страница 182: ...3 2 Programming your System ST 25 DECT 30 ST 30...
Страница 205: ...3 25 Programming your System ST 25 DECT 30 ST 30...
Страница 221: ...S 5 Index...
Страница 222: ...S 6 Index...
Страница 224: ...S 8 Index Declaration of Conformity...
Страница 225: ...S 9 Index Declaration of Conformity...
Страница 226: ...S 10 Index Declaration of Conformity...
Страница 227: ...S 11 Index...