Agelkom CAP04-V Manual
6
Internal Coil Adjustment:
Mount CAP04 and Sensor Head with Sensor Ring to your machine.
Keep Sensor Ring to Working Plate distance at maximum (at least 10cm).
Important
:
Do not turn more than ½ tour CW or CCW and do not apply force to the CORE of the internal
coil. The CORE is easily broken. Use plastic screw driver. It is not a SESITIVITY adjustment.
Smoothly close some metal plate (say 20cm x 20cm) to sensor ring and observe that voltage increase
(never decrease) come to closer.
1
HEIGHT CONTROL KNOB
TURN FULLY CCW
2
CONNECT DVM – to
HOOK with Black Bead
or (
-
) of your Supply
3
CONNECT DVM +
TO TEST POINT HOOK
With Orange Bead
GAP
ADJUSTMENT
SENSOR
ADJUSTMENT
COIL
SENSOR HEAD
CONNECTOR
CW Coil
Fully
CCW
V
o
lt
ag
e
Correct Adjustment Point
4
ADJUST INNER COIL
TO MINUMUM VOLTAGE
1-3 volts