Technical Specifications: 
Supply:  Nominal 24VDC 100mA, Max: 30VDC  Min: 18VDC 
Current:  Less than 100mA  
Protection:  Against supply reverse voltage. 
All Outputs: Normally high at 15V, 15mA with current limiter resistor.  

Can be drive opto-coupler directly 

Sensor Cable:  90cm Length, Type RG59 
 

WHITE IN POSITION

 

BROWN TOUCH   

SENSOR POWER +24VDC 

SENSOR POWER 0V 

AGELKOM 
CAPACITIVE 
SENSOR 

CAP04 V 

  

CABLE COLORS 

RED  +  24v 

GREEN  DOWN 

YELLOW UP 

CONNECTOR 

PIN NUMBER

 

Simplified typical connection of CAP04-V shown below. 

 

CABLE SHIELD  

POWER SUPPLY / SYSTEM GROUND 

Breakout Board 

To PC, Port 2, pin # “Torch Down input”   

To PC, Port 2, pin # “Torch Up input”   

To PC Port Ground   

I/O board 

User defined PC Port# and pin# 

To PC Port 2,  pin #  “Probe input” 

To PC, Port 2, pin # “User Defined input”   

BLUE  0V 

GREY HEIGHT V 

+

 

PINK HEIGHT V 

-

 

To PC Port 2,  pin #  “Spindle Output” 

Analog 

Out 

0-10VDC

 

 

Narrow 

Wide 

TOUCH  

ADJUSTMENT 

CCW Turn-off 

the LED 

DOWN 

IN POS 

UP 

TOUCH 

CABLE  

SENSOR HEAD  
BNC

 

CONNECTOR 

SENSOR 

ADJUSTMENT 

COIL 

Adjust 1 volt 

at Orange bead 

GAP  

ADJUSTMENT

 

8 PIN 

CONNECTOR 

 

Connect DVM    
for COIL adj. 

Common Point 
for Adjustment 

Black bead 

Connect DVM     

Height / Voltage 
Adjust 10V (white bead)  
at 10V Control Input 

  

10V(white bead)  
Test Point 

  

PWM Disable 
Jumper 

  

 

Height Control Input is floating 
against ground loop problem. 
 
Adustment procedure as follows: 
Apply these input 10VDC and adjust 
trimmer potentiometer until to read at 
WHITE BEAD about 10V. Reduce 
control voltage about 3 volts and 
measure 13.67V at same test point.  
Between 0 to 3Volts, controlling is 
disabled for the noise margin. 
If no voltage applied, the same voltage 
appear about 13.67V. This is the 
Maximum Height Level  
 
All adjustment made at factory. Please 
do not change until it is necessary. 

Содержание CAP04

Страница 1: ...ly low 15V level during in active and drive up to 15mA These outputs can directly drive LED or Opto Coupler Due to current limiting there is no need voltage divider for 12 and 5 volts input range of y...

Страница 2: ...sor and observe down output is activated in your HOME position or sufficiently high above the plate If DOWN LED is activated instead of UP readjust the core of the coil 3 Start slowly to decrease the...

Страница 3: ...cutting material Turn CW until TOUCH LED is ON APPLICATION During plasma cutting sensor ring and plasma torch are in the same height This will allow to use TOUCH output as a collision detection means...

Страница 4: ...ined input BLUE 0V 7 8 GREY HEIGHT V PINK HEIGHT V To PC Port 2 pin Spindle Output Analog Out 0 10VDC Narrow Wide TOUCH ADJUSTMENT CCW Turn off the LED DOWN IN POS UP TOUCH CABLE SENSOR HEAD BNC CONNE...

Страница 5: ...at 15V and 15mA Check your input and configure for ACTIVE HIGH Your inputs must be 0V level and Pull Up resistor not used If your BREAKOUT BOARD has OPTO COUPLER inputs at 5V level you can connect di...

Страница 6: ...ly broken Use plastic screw driver It is not a SESITIVITY adjustment Smoothly close some metal plate say 20cm x 20cm to sensor ring and observe that voltage increase never decrease come to closer 1 HE...

Страница 7: ...ype Ground Connection Use thick wire 10mm GROUNDING MOUNTING Dimensions are in mm Case Size 116 65 31 Two mounting holes are shown in red Machine Chassis CW Coil Fully CCW Sensig Height Down Led is ON...

Страница 8: ...Agelkom CAP04 V Manual 8 69 mm dia 47 mm dia 67mm approx Mounting Details...

Отзывы: