AGELKOM CAP04 Скачать руководство пользователя страница 3

Agelkom CAP04-V Manual 

 

Touch (Down Limit) Adjustment: 

After all adjustment was finished, you can start to adjust Down Limit potentiometer, adjust 
this multiturn trimmer potentiometer (turn CCW) until TOUCH  LED is OFF Afterwards, 
close the sensor ring until it touches the plate or insert paper between sensor ring and plate 
(cutting material). Turn CW until TOUCH LED is ON

 

 
APPLICATION: 

During plasma cutting, sensor ring and plasma torch are in the same height. This will allow 
to use TOUCH output as a collision detection means. If any fault occurs, the UP output 
activate automatically. 
During thick plate cutting, dross may touch the sensor ring and the torch head lifted. To 
avoid this situation correct your cutting parameters for less dross.  
 
CAP04-V can be used with voltage controlled Height Control System. The two systems are 
OR’ed. 
 

 

 

 

67mm approx

.  

Содержание CAP04

Страница 1: ...ly low 15V level during in active and drive up to 15mA These outputs can directly drive LED or Opto Coupler Due to current limiting there is no need voltage divider for 12 and 5 volts input range of y...

Страница 2: ...sor and observe down output is activated in your HOME position or sufficiently high above the plate If DOWN LED is activated instead of UP readjust the core of the coil 3 Start slowly to decrease the...

Страница 3: ...cutting material Turn CW until TOUCH LED is ON APPLICATION During plasma cutting sensor ring and plasma torch are in the same height This will allow to use TOUCH output as a collision detection means...

Страница 4: ...ined input BLUE 0V 7 8 GREY HEIGHT V PINK HEIGHT V To PC Port 2 pin Spindle Output Analog Out 0 10VDC Narrow Wide TOUCH ADJUSTMENT CCW Turn off the LED DOWN IN POS UP TOUCH CABLE SENSOR HEAD BNC CONNE...

Страница 5: ...at 15V and 15mA Check your input and configure for ACTIVE HIGH Your inputs must be 0V level and Pull Up resistor not used If your BREAKOUT BOARD has OPTO COUPLER inputs at 5V level you can connect di...

Страница 6: ...ly broken Use plastic screw driver It is not a SESITIVITY adjustment Smoothly close some metal plate say 20cm x 20cm to sensor ring and observe that voltage increase never decrease come to closer 1 HE...

Страница 7: ...ype Ground Connection Use thick wire 10mm GROUNDING MOUNTING Dimensions are in mm Case Size 116 65 31 Two mounting holes are shown in red Machine Chassis CW Coil Fully CCW Sensig Height Down Led is ON...

Страница 8: ...Agelkom CAP04 V Manual 8 69 mm dia 47 mm dia 67mm approx Mounting Details...