AGELKOM CAP04 Скачать руководство пользователя страница 2

Agelkom CAP04-V Manual 

ADJUSTMENT: 

1. 

Apply 10V DC to Height Control 

inputs. Adjust Height/Voltage 
trimpot until 10V reading at 
WHITE bead. Manually adjust the 
torch lifter, so the ring is about 50 
mm above the plate. 

2. 

Disable the drive system (e.g. 

electrically or mechanically 
disconnect motor).  

3. 

Activate CAP04 and monitor up 

and down output. At this point 
DOWN (GREEN) LED must be 
on, if not internal coil adjustment 
needed. (Refer Internal Coil 
Adjustment Section). 

4. 

Decrease the distance between 

sensing ring and plate and verify 
that UP (AMBER) LED is ON. 

5. 

Disconnect BNC connector and 

verify that CABLE (RED) LED is 
ON.  

6. 

Reconnect the drive system. 

 

The correctly adjusted sensor should activate outputs /- 0.05 mm at 1.5 mm above 

the plate and up to +/- 0.2 mm at 35 mm. with two sensor. 

 

Internal Coil Adjustment: 

(if necessary)

 

1. Do not apply Height Control Voltage. This is for maximum height. 
2. In Home position of your Z axis DOWN LED must be ON, if not: 

Remove the front panel. Use plastic screw driver. Gently adjust of the internal coil of 

CAP04 sensor and observe down output is activated in your HOME position (or 
sufficiently high above the plate.) If DOWN LED is activated instead of UP readjust 
the core of the coil.  

3. Start slowly to decrease the distance between sensing ring and the plate to the cutting 

height of say 3mm and verify that UP LED is ON. If not, readjust the coil. 

4. If you need to change the cable between the unit to sensor ring, internal coil should be 

re-adjusted. You can use 70 cm to 100 cm long sensor cable. The original cable length 
is 90 cm and the type is RG59 
 

Important

Do not turn more than ½ tour CW or CCW and do not apply force to the CORE 
of the internal coil. The CORE is easily broken. It is not a SESITIVITY 
adjustment 
 
Window Adjustment: 

There is small amount of GAP (window) between UP and DOWN. Also GAP could 
be adjusted with internal trimpot. Turning CW of trimpot makes gap wider. Increased 
cutting height will result in a wider the GAP. 

 

Narrow 

Wide 

TOUCH  

ADJUSTMENT 

CCW Turn-off 

the LED 

GAP  

ADJUSTMENT

 

Common Point 
for Adjustment 

Black bead 

Connect DVM     

8 PIN 

CONNECTOR 

 

Connect DVM    
for COIL adj. 

DOWN 

IN POS 

UP 

TOUCH 

CABLE  

SENSOR HEAD  
BNC

 

CONNECTOR 

SENSOR 

ADJUSTMENT 

COIL 

Adjust 1 volt 

at Orange bead 

Height / Voltage 
Adjust 10V (white bead)  
at 10V Control Input 

 

 

Содержание CAP04

Страница 1: ...ly low 15V level during in active and drive up to 15mA These outputs can directly drive LED or Opto Coupler Due to current limiting there is no need voltage divider for 12 and 5 volts input range of y...

Страница 2: ...sor and observe down output is activated in your HOME position or sufficiently high above the plate If DOWN LED is activated instead of UP readjust the core of the coil 3 Start slowly to decrease the...

Страница 3: ...cutting material Turn CW until TOUCH LED is ON APPLICATION During plasma cutting sensor ring and plasma torch are in the same height This will allow to use TOUCH output as a collision detection means...

Страница 4: ...ined input BLUE 0V 7 8 GREY HEIGHT V PINK HEIGHT V To PC Port 2 pin Spindle Output Analog Out 0 10VDC Narrow Wide TOUCH ADJUSTMENT CCW Turn off the LED DOWN IN POS UP TOUCH CABLE SENSOR HEAD BNC CONNE...

Страница 5: ...at 15V and 15mA Check your input and configure for ACTIVE HIGH Your inputs must be 0V level and Pull Up resistor not used If your BREAKOUT BOARD has OPTO COUPLER inputs at 5V level you can connect di...

Страница 6: ...ly broken Use plastic screw driver It is not a SESITIVITY adjustment Smoothly close some metal plate say 20cm x 20cm to sensor ring and observe that voltage increase never decrease come to closer 1 HE...

Страница 7: ...ype Ground Connection Use thick wire 10mm GROUNDING MOUNTING Dimensions are in mm Case Size 116 65 31 Two mounting holes are shown in red Machine Chassis CW Coil Fully CCW Sensig Height Down Led is ON...

Страница 8: ...Agelkom CAP04 V Manual 8 69 mm dia 47 mm dia 67mm approx Mounting Details...