24
AGA Ellesmere Standard Gas Stove
3.5 Flue Connection
3.5.1 General notes
This appliance may be installed with a roof terminal (C31) or a wall terminal (C11).
This appliance may only be used with 100/150 sized Balanced Flue (otherwise known as Concentric
Flue) parts as specified by AGA Stoves. The AGA Stoves specified flue parts have been approved with
the appliance. If the appliance is installed on non-AGA Stoves approved parts, AGA Stoves cannot
guarantee or accept any responsibility for the proper and safe working of the appliance. This will also
void all warranty cover
The flue system must be constructed from the appliance vertically upwards from the top of the stove or
horizontally out of the rear of the stove, with all joints being fully locked and sealed using the AGA
Stoves specified parts.
This stove can be flued out of the rear of the stove or out of the top of the stove, the 2 x flue collars are
supplied loose and the installer needs to fit them as per the following instructions, it is very important that
the following instructions are adhered to
PLEASE NOTE - ONLY AGA APPROVED FLUE CAN BE FITTED TO THIS STOVE
The Approved AGA Flue Collars
–
Manufactured in Stainless Steel
– these are supplied loose inside
the fire box of the stove
Inner Flue Collar is 100mm outer diameter, it is supplied in the
firebox, the seal has been fitted to it already
– please make
sure there is no damage to the flue seal. This flue collar
allows the exhaust gases to be removed from the stove
The Outer Flue Collar is 150mm outer diameter, it is supplied
in the firebox, the seal has been fitted to it already
– please
make sure there is no damage to the flue seal. This flue collar
allows the fresh air to be delivered into the stove