afx light 16-2675 Скачать руководство пользователя страница 3

© Copyright LOTRONIC 2019                          PARCOB150WH-MKIII 

Page  3 

2. Connection of Signal Cable 
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave light. Connect 
the DIGITAL OUT socket of the master and the IN socket of the slave light, then, connect the OUT socket to the IN socket of 
the next light. Ordinal to connect all the lights as below: 

IN

O U T

IN

O U T

O U T

IN

1

2

3

D

M

X

  IN

DM
X  O

UT

 

The connection between the output of master and input of product, it’s available to use the 3 pins XLR cable which provided 
by the manufacturer. Signal cable from the DMX output of the controller to the input of the first master light, and connect to 
the DMX input of second slave light from the DMX output of the first master light, analogously, till connected all the slave 
lights, and insert the last connector to the output of the final light. (Notice: the diameter of core of every cable should be 
0.5mm at least, double core shelter cable should be used).The signal connecting must use the attached 3 pins XLR cable. 
Notice, all the internal lead wire of the 3 pins XLR cable should not touch to each other or connect to the connector. 
 
A DMX signal terminator is recommended on the last unit of the ch

ain.  DMX  terminator  is  a  XLR  connector  with  a  120Ω 

resistor between the pin 2 and pin 3 of the XLR connector   
 

RIGGING 

This fixture may be mounted in any position, provided there is adequate room for ventilation 
It is important never to obstruct the fan or vents pathway.   
When selecting installation location, take into consideration lamp replacement access and routine maintenance.   
Safety cables must always be used. 
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted 
ventilation. 
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his 
service agent or a similar qualified person in order to avoid a hazard. 
 

Features 

 

5 channel DMX-512 

 

Variable electronic strobe. 

 

Variable electronic dimmer (0-100%) 

 

Digital LED display   

 

Reset to factory settings option. 

 

Color temperature setting 

 

Software-controlled temperature sensor to control fan speed to prevent overheating 

 
OPERATION 

After you connected the effect to the mains, the fixture starts running. 

Stand Alone operation 

In the stand alone mode, the fixture can be use without controller 

Master/slave-operation 

The master/slave-operation allows several devices to be synchronized and controlled by one master-device   

DMX controlled operation 

You can control the projectors individually via your DMX-controller 

 

Содержание 16-2675

Страница 1: ...R R A A L LE ED DS S L LE ED D P PR RO OJ JE EC CT TO OR R L LE ED D S ST TR RA AH HL LE ER R P PR RO OJ JE EC CT TO OR R L LE ED D GB INSTRUCTION MANUAL F MANUEL D UTILISATION D BEDIENUNGSANLEITUNG N...

Страница 2: ...rofessionals The light doesn t include any spare parts for repair please check if all the parts are well installed and screws are fitted tightly before operating Do not use the light when the cover is...

Страница 3: ...on the last unit of the chain DMX terminator is a XLR connector with a 120 resistor between the pin 2 and pin 3 of the XLR connector RIGGING This fixture may be mounted in any position provided there...

Страница 4: ...n leave every mode by pressing the Mode Esc button The functions provided are described in the following setting MENU MAP The device has two operation modes It can be operated in manual or DMX mode Wh...

Страница 5: ...ES DE SECURITE ET D UTILISATION Si l appareil a t expos des changements de temp rature ne le mettez pas imm diatement sous tension La condensation qui peut se produire risque d endommager les circuits...

Страница 6: ...is s avec ses fonctions Ne pas autoriser une personne inexp riment e d utiliser cet appareil La plupart des dommages r sultent d une mauvaise utilisation Conservez l emballage d origine pour tout tran...

Страница 7: ...reils de fonctionner en synchrone en suivant un appareil ma tre Fonctionnement contr l par DMX Vous pouvez commander les projecteurs individuellement via une commande DMX R glage de l adresse DMX Vous...

Страница 8: ...X Canal Valeur Fonction 1 0 255 Dimmer Variateur 0 100 2 0 255 Blanc froid 0 100 3 0 255 Blanc chaud 0 100 4 0 10 11 255 Strobo Pas de fonction Stroboscope avec vitesse croissante 5 0 9 10 29 30 69 70...

Страница 9: ...icken Sie kann bei empfindlichen Personen epileptische Anf lle ausl sen Sch den die durch die Nichtbeachtung der Anweisungen oder durch unbefugte Ver nderungen am Ger t entstanden sind werden nicht vo...

Страница 10: ...Wartung ber cksichtigt werden Immer Sicherheitskabel benutzen Niemals an Stellen anbringen wo das Ger t Regen hoher Feuchtigkeit extremen Temperaturschwankungen oder ungen gender Bel ftung ausgesetzt...

Страница 11: ...rden Im Master Slave Betrieb kann nur ein Ger t als Master eingestellt werden STAT ST 00 Einstellung des Stroboskopeffekts von 0 20 A 000 Einstellung von Kaltwei von 0 255 B 000 Einstellung von Warmwe...

Страница 12: ...Er kan condensatie optreden die het apparaat beschadigt Zet het apparaat niet aan voordat het de kamertemperatuur heeft bereikt Dit apparaat behoort tot beschermingsklasse I Het moet dus verplicht wo...

Страница 13: ...een andere manier wordt gebruikt dan beschreven in deze gebruiksaanwijzing kan het product beschadigd raken en de garantie vervallen 1 Aansluiting van de voedingskabel Gebruik de meegeleverde kabel o...

Страница 14: ...Stel het DMX adres d m v de controle panel in Let op Een DMX signaal afsluitweerstand moet aan de uitgang van het laatste toestel aangesloten worden voor een goede signaal transmissie CONTROLE PANEEL...

Страница 15: ...mmer 0 100 dimmer 2 0 255 Koud wit 0 100 3 0 255 Warm wit 0 100 4 0 10 11 255 Stroboscoop Geen functie Stroboscoop met stijgende snelheid 5 0 9 10 29 30 69 70 129 130 189 190 255 Dimmer Optionaal Dimm...

Страница 16: ...e as de reposi o para repara o por favor verifique se todas as pe as est o bem instaladas e os parafusos est o firmemente ajustados antes da opera o N o utilize o aparelho com a tampa aberta Este disp...

Страница 17: ...cais com exposi o chuva humidade elevada mudan as extremas de temperatura ou ventila o restrita Se o cabo flex vel externo ou o cabo de alimenta o estiver danificado deve ser exclusivamente substitu d...

Страница 18: ...apenas uma unidade pode ser ajustada para MASTER STAT ST 00 Efeito do estrobosc pio ajust vel entre 0 20 A 000 Branco frio ajust vel entre 0 255 B 000 Branco quente ajust vel entre 0 255 RUN Op o entr...

Страница 19: ...amento 100V 240V 50 60Hz Consumo 200W LED LED COB 2 em 1 branco quente e branco frio Peso bruto 3 6Kgs Dimens es 370 H x 300 W x 300 L mm Os produtos el ctricos n o devem ser colocados no lixo dom sti...

Страница 20: ...Copyright LOTRONIC 2019...

Отзывы: