![Afriso EURO-INDEX D0 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/afriso-euro-index/d0/d0_operating-instructions-manual_2864879026.webp)
Mounting and commissioning
26
Bourdon tube, capsule, diaphragm, spring diaphragm pressure gauges
7.3
Mounting position
The orientation is indicated by the orientation mark on the dial.
a
Symbol
b
Meaning
c
Dial
Fig. 6: Orientation mark as per EN 837
If no orientation mark is indicated on the dial, the pressure gauge
must be mounted vertically (as per EN 837).
Pressure gauge and chemical seal with 3A approval
The fluid must be able to flow off.
Do not mount the pressure gauge and the chemical seal "up-
side down".
Parts welded to the tank must be mounted flush with the inside
wall of the tank (
1
). The surface roughness R
a
of the welding
seams must not exceed 0.8.
Fig. 7: At T piece
At tank