![Afriso EURO-INDEX D0 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/afriso-euro-index/d0/d0_operating-instructions-manual_2864879015.webp)
Technical specifications
Bourdon tube, capsule, diaphragm,
spring diaphragm pressure gauges
15
5
Technical specifications
Table 1: Technical specifications Bourdon tube pressure gauges
Parameter
Value
General specifications
Measuring ranges
-1/0 bar to -1/15 bar
0/0.6 bar to 0/1600 bar
Temperature perfor-
mance
Rising temperature approx. +0.4 %/K
Falling temperature approx. -0.5 %/K
(indication error when the temperature
of the measuring system deviates from
the normal temperature of 20 °C, with
reference to the full scale value)
Operating frequency in
hazardous areas (EX
areas).
Max. 0.1 Hz
Operating temperature range
Ambient
-20 °C to +60 °C
Fluid
Max. +60 °C for liquid filled devices and
devices with soft-soldered Bourdon
tubes
Max. +100 °C for non-filled devices with
hard-soldered or welded bourdon tube
Storage
-40 °C to +70 °C
Application area with static load
Up to full scale value
Type: D4, D5, D8
Type: D2, D3
Type: D1
In NS 100, NS 160, NS 250 (cl. 1.0 up
to
≤
600 bar)
In NS 100 (cl. 1.0)
In NS 4½"
Up to ¾ full scale value
Type: D1, D6, D7, D9,
D0
Type: D2, D3, D4, D8
Type: D2
Type: D4
All nominal sizes
In NS 40, NS 50, NS 63, NS 80
In NS 100 (cl. 1,6)
In NS 160, NS 250 (cl. 0.6 cl. 0.25
cl. 0.1 and cl. 1.0 > 600 bar)