![Afriso EURO-INDEX D0 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/afriso-euro-index/d0/d0_operating-instructions-manual_2864879020.webp)
Technical specifications
20
Bourdon tube, capsule, diaphragm, spring diaphragm pressure gauges
Table 6: Technical specifications spring diaphragm pressure gauges
(differential pressure)
Parameter
Value
General specifications
Measuring ranges
0/250 mbar to 0/6 bar
Temperature perfor-
mance
Rising temperature approx. +0.05 %/K
Falling temperature approx. -0.05 %/K
(indication error when the temperature
of the measuring system deviates from
the normal temperature of 20 °C, with
reference to the full scale value)
Operating temperature range
Ambient
-20 °C to +60 °C
Fluid
Max. +60 °C
Attention:
Fluid must not freeze.
Storage
-40 °C to +70 °C
See the current AFRISO catalogue or www.afriso.com for additional
technical specifications
5.1
Approvals, tests and conformities
Bourdon tube pressure gauges comply with the European standard
for pressure measuring instruments EN 837-1, capsule pressure
gauges and diaphragm pressure gauge comply with EN 837-3.
Pressure gauges with a full scale value e 500 mbar comply with the
Pressure Equipment Directive (2014/68/EU).
Bourdon tube pressure gauges with clamp chemical seal
The pressure gauges also comply with the US standard 3-A Sanitary
Standard 74-03.
Bourdon tube pressure gauge NS50 with inductive contact
The pressure gauges also comply with the ATEX directive
(2014/34/EU).