Transport and storage
Bourdon tube, capsule, diaphragm,
spring diaphragm pressure gauges
21
6
Transport and storage
CAUTION
Damage to the pressure measuring instrument, reduced accu-
racy or leaks at the measuring system due to improper trans-
portation
Do not throw or drop the product.
CAUTION
Damage to the product due to improper storage.
Store the product in a clean and dry environment.
Only store the product within the permissible temperature range.
7
Mounting and commissioning
Safety information on mounting
For pressure gauge with blow-out device: The blow-out device
must not be blocked by parts or by dirt.
The distance between the blow-out device and other objects
must be at least 20 mm.
Never hold the housing of a pressure gauge when mounting or
dismounting it.
In order to avoid damage to the pressure gauge, always use a
suitable spanner to apply the tightening torque to the appropri-
ate areas at the connection piece.
When the pressure connection piece of a wall-mounted or pan-
el-mounted pressure gauge is tightened, always hold the con-
nection piece with a suitable spanner in order to help avoid