40
If so, press RESET and start again.
If the display reads “Time Out”, you have missed a mark and will have to restart the machine
If the paper feed motor is under undue stress for a period of time, the machine can shut down
as a safety thermal overload is activated.
Shut the machine down and wait a couple of minutes, then re-start.
My machine stalls and slows, when I turn the speed dial above 6
The converter uses a .4kw inverter drive for the index motor, which is a .4kw motor. As a
protective measure, the motor will not allow more power than its maximum to be used. The
speed pot should not be run past the point where this happens, as it will simply slow the
production down. Generally, this has been altered in the inverter settings.
I am running full stroke on my die (305mm) and the cylinder carriage
is hitting the end stops.
There is a separate speed control for the Die cylinder motor. It should normally be set to
maximum on the pot but if in the case of a full stroke job, the cylinder is touching the ends,
simply lower the speed of the cylinder slightly until this does not occur. It is located, on the
electrical box.
Do not allow the cylinder to hit the ends constantly, as damage will result.
Содержание DLP-2000