12
Overview
Menu Review
Jump1
Die Length
: Length of die + 20mm.
Stroke:
This is the drive pulley teeth count. The value is set automatically by converter.
Rotary Mode (M
): Sets the length of stock to be run when in full rotary mode.
METERS REM (M
): Displays the number of meters remaining in the job, when in full rotary mode.
Jump2
Labels Required
: Enter number of labels to convert, noting that one label will include the number of
labels on the die. Example, die contains 6 labels. If 100 is entered in label count, 600 blank labels will be
produced.
Label Count
: Number of labels produced. Press CLR to reset label count. Same rule applies, stated
above.
Count:
1 is on, 0 is off.
Jump3
Unwinder:
Does not apply. Should be 0
Loop Sensor:
1 is enabled, 0 is disabled. Enabled when printing in line. Disabled when not using printer.
Cutter Qty:
Does not apply. Should be 0001
(Page 2 settings in Jump3 are the same as in Jump5)
Jump4
Encoder Read: The amount the encoder has currently read in its cycle. This value cannot be changed.
CAL: This value is preset at the factory. Do not change.
Encoder Mark: 1/3 of the distance of the die length
ENC. Fast: Value of zero.
ENC O/Run: Value of 000.8
Index T/Out: Distance the converter will run before stopping because the black mark was not
detected. Set this value to 1.5 times the repeat value
Jump5
Encoder Indexing
: Always set to 1. Do not change.
Repeat
: distance from the middle of one black mark to the next (pitch)
Sense
: distance the laser starts to look for the next black mark. Set to 0 if making blanks in
reciprocating mode.
Jump6
Dig-IN
: 10001000
ADIG-IN
: 10010000
These are used for troubleshooting. These values indicate that a low voltage part is working. If you
trigger a sensor, i.e.; move the encoder, hold a metal object in front of a proximity switch, cause the
laser sensor to see something by lighting up (or turning off its light) or making the loop sensor "see"
something and you get no value change on the screen in any digit, then you know that the sensor is
faulty or not being recognized by the machine. It is a simple way of narrowing down an unexpected
fault to a particular device. Not all digits are used.