AfiMilk MPC
Installation Manual
97
Unique Setup & Configurations
Chapter
8
Setting-up MPC Extender
MPC extender
is
enabled and set via
AfiControl
configuration screens.
When inside the configurator, check the
MPC Extender
box to enable the option
Open each of the "
Out
" port drop-down lists to select the desired option. Note
that each
out
supports one of two pre-defined features per the table below:
Example: Out 3 functional options
Port Number
Option 1
Potion 2
Out 1
Milk Classification
(MCS)
Milk Separation
Out 2
Retention Bar
(Rotary Parlor)
--
Out 3
Backflush (Air
Output)
Auto Teat Spray
(Rotary Parlor)
Out 4
Backflush (Water
Output)
Strip