Adjusting the “G” Parameter Value
Change the value of "
G
" parameter per calculated average deviation. If the result is
negative (Milk meter reading is lower than the actual weight), the calculated adjustment
value needs to be added to the value of
G
. If the adjustment is positive, the calculated
value needs to be subtracted from the value of
G
.
General adjustment calculation →%Dev X (–2.5) = Adjustment value
Example
: if the actual value of G in the milk meter is
55
and the measured deviation
-4%
(Milk meters show 4% less than actual weight)
, modify the “G” parameter
value by:
-4 X (-2.5) = +10 to 65
Use the same procedure explained above for Air Admission Compensation for accessing
and changing the value of G parameter.
Adjusting the “H” Parameter Value
Change the value of "
H
" parameter per calculated average deviation. If the result is
negative (Milk meter reading is lower than the actual weight), the calculated adjustment
value needs to be added to the value of
H
. If the adjustment is positive, the calculated
value needs to be subtracted from the value of
H
.
General adjustment calculation →
%Dev X (–5) = Adjustment value
Example
: if the actual value of
H
in the milk meter is
37
and the measured deviation
-4%
(Milk meters show 4% less than actual weight)
, modify the “
H
” parameter
value by:
-4 X (-5) = +20 to 57
Check the accuracy of the new settings within a few days after setting the
new “G” value. This may be done by comparing total milk collected by
the afimilk system to the bulk tank accumulation
.
NOTE
Содержание MPC 3
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 14: ......
Страница 22: ...Chapter 3 Operation Sequence AfiMilk MPC Installation Manual 22 Milking Sequence at Afimilk MPC...
Страница 31: ...Figure 8 Layout of Vacuum and Clean air Lines For Milk Meter Solenoids...
Страница 32: ......
Страница 64: ......
Страница 80: ......
Страница 96: ...Chapter 8 Unique Setup Configurations MPC Extender Connections Diagram...
Страница 98: ......
Страница 110: ...Chapter 11 Systems Accessories AfiMilk MPC Installation Manual 110...
Страница 113: ...AfiMilk MPC Installation Manual 113 Parts List Chapter 12...