105
o
E02
Error message:
resistance to milk discharge, where the milk is not
discharged quickly enough. This alert appears after cluster removal to
indicate a possible milk measuring inaccuracy.
o
E02F
= dramatic discharge problem
: The milk meter is not emptied and
milk overflows through the measuring chamber. This alert appears
immediately, as soon as the error is indicated. This problem usually occurs
due to a valve or another severe mechanical malfunction. In such
situations,
afimilk MPC
stops measuring although pulsation continues to
function.
o
If such happen check the following :
a.
If the elbow pipe connecting the milk meter outlet port to
the milk line is at a downwards slope towards the milk line
b.
If air orifice in the milking claw is open
c.
If at cleaning mode the valve is moving up and down
properly (if not, the body solenoid may be faulty OR the
solenoid diaphragm may be damaged).
Содержание MPC 3
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 14: ......
Страница 22: ...Chapter 3 Operation Sequence AfiMilk MPC Installation Manual 22 Milking Sequence at Afimilk MPC...
Страница 31: ...Figure 8 Layout of Vacuum and Clean air Lines For Milk Meter Solenoids...
Страница 32: ......
Страница 64: ......
Страница 80: ......
Страница 96: ...Chapter 8 Unique Setup Configurations MPC Extender Connections Diagram...
Страница 98: ......
Страница 110: ...Chapter 11 Systems Accessories AfiMilk MPC Installation Manual 110...
Страница 113: ...AfiMilk MPC Installation Manual 113 Parts List Chapter 12...