AR24027
Operator’s Manual
A-2
Major Configuration Parameters
Command
Parameters
Values
Factory
Configuration
distance-max
kilo-meters
16..160
80
miles
10..100
50
ethernet
speed
auto-10, 10hdx, 10fdx
100hdx, 100fdx, auto
auto
timeout-sec
5..10000
30
multi-cast-timeout-sec
5..10000
600
node
type
hub, remote
remote
max-remotes
1..32
32
name
(23 character string)
rmt-nnnnn (PmP)
network-id
0..65535
0
location
(25 character string)
contact
(25 character string)
rf-receive-setup
channel
3..37
20
antenna
a, b
a
rf-transmit-setup
channel
3..37
20
antenna
a, b
a
speed-mbps
0.25, 0.50, 1.37, 2.75
2.75
power-dbm
0..23
18
single-node-reboot
timeout-sec
15..20000
900
time-division-duplex
sync-mode
off, auto
auto
cycle-period-ms
10, 20, 30, 40
20
transmit-percent
auto, 10, 20, 30, 40,
50, 60, 70, 80, 90
auto