and allows you to download to multiple radios from the same PC. (2) Using a Telnet session from
anywhere on the Internet. This requires the radio to have been pre-configured with an IP address. (3)
Using a terminal emulator program (e.g. HyperTerminal) running on a PC connected through the
serial port to the radio RS-232 auxiliary port. This method only allows you to download to that
specific radio.
The next three sessions explain in detail how to download a new file using each method.
3.3.2
Installing new firmware through the Ethernet port
This procedure assumes that the new firmware needs to be installed in all radios of a working
network. The upgrade is performed from a single PC connected via Ethernet to one of the radios.
Note that new firmware does not need to be compatible with the firmware currently running. You
can still download incompatible firmware and restart the network from a single location.
1.
If you have not done so, install the utility program “econ” in the PC. This utility program is
distributed with the radios and can also be downloaded from the website. Please refer to
appendix D for instructions on how to install this utility.
2.
Make sure the file with the new firmware (file pmpNN_NN.bz) is available in the PC.
3.
Start the econsole utility by typing “econ” from a DOS window. Econ will send a “discovery”
message and display all the radios that can be seen. Verify that all radios in the network are
listed. Then select one of the radios in the list that you wish to upgrade.
4.
Issue the command:
>directory
to view a list of files stored in Flash PROM as well as the available free space. Verify that the
free space in flash PROM is larger than the size of the pmpNN_NN.bz file in the PC. If there is
not enough space in Flash PROM delete one of the program files to make up space (use command
>delete filename).
5.
If the radio configuration has been password protected, you must first unlock the protection with
the command:
>
unlock enable-configuration=
password
(when the configuration is unlocked, the radio prompt ends with the characters ‘#>. In locked
mode the prompt does not include the ‘#’ character).
6.
Issue the command:
>download
path/
pmpNN_NN.bz
where
path/
is the directory in the PC where the pmpNN_NN.bz file is stored. The
path/
extension is not required if the file is in the same directory as the ECON program. As the
download proceeds econ displays a line showing the current percentage complete.
7.
Once the download is complete, issue the command:
>set-default-program pmpNN_NN
in order to make the new file the default program to run after a reset.
Содержание AR24027
Страница 5: ...AR24027 Operator s Manual iv ...
Страница 15: ......
Страница 25: ......
Страница 41: ......
Страница 61: ......
Страница 76: ...AR24027 Operator s Manual 6 11 Figure 6 3 Free Space Path Loss at 2 4 GHz ...
Страница 85: ...AR24027 Operator s Manual B 2 ...
Страница 87: ...AR24027 Operator s Manual C 2 ...
Страница 93: ......
Страница 96: ......
Страница 98: ......