AR24027
Operator’s Manual
4-5
password), otherwise the lock command has no effect. If a password is set, the radio
automatically “locks” the configuration at the end of 10 minutes with no command activity.
save-configuration
destination=main
or
alternate
Saves the current set of radio operating parameters into one of the two non-volatile
configurations. If the destination is not specified it defaults to “main”.
Examples:
>
save-configuration destination=alternate
>
save
unlock
debug-mode=”ASCII string”
enable-configuration=”ASCII string”
This command unlocks the access to various commands. The
enable-configuration
password
(set with the change-password command) unlocks the various commands listed in this manual
that alter the radio configuration. The
debug-mode
is a factory mode used for troubleshooting
by customer support.
Examples:
> unlock enable-configuration=bh7g8
4.4
Major Configuration Parameters
These commands change several operating parameters of the radio that are part of the radio
configuration. When entering commands with multiple parameters, if a parameter is not
included, that parameter keeps its current value.
distance-max
kilo-meters=16..160
miles=10..100
Sets the limit for the maximum distance of the RF link. In general you should leave this
parameter set to the default value of 80 Km (50 miles). But if you are deploying a link that
exceeds this distance you must change this parameter to a value that is equal or greater than the
link distance.
All nodes in the network must have this parameter set to the same value. For example, in a
point to multipoint network where only one link exceeds the nominal 80 Km, you must still set
all nodes in the network to the new value.
Increasing this parameter results in a slight decrease of throughput offered by the radios.
Содержание AR24027
Страница 5: ...AR24027 Operator s Manual iv ...
Страница 15: ......
Страница 25: ......
Страница 41: ......
Страница 61: ......
Страница 76: ...AR24027 Operator s Manual 6 11 Figure 6 3 Free Space Path Loss at 2 4 GHz ...
Страница 85: ...AR24027 Operator s Manual B 2 ...
Страница 87: ...AR24027 Operator s Manual C 2 ...
Страница 93: ......
Страница 96: ......
Страница 98: ......