Installation, assembly & setting
Assembly instructions EN
GE-25-P
Date 02.11.2021
Version 1.0
29–48
6.3 Mechanical connection
6.3.1 Flatness of the mounting surface
The values given below refer to the entire screw-on surface on which the GE-
25-P are mounted.
Edge lengths
Admissible unevenness
< 100
< 0.02
> 100
< 0.05
Requirements for the evenness of the screw-on surface (dimensions in mm)
6.3.2 Connections on the housing
The GE-25-P can be mounted from three sides.
Fig. 6
Options for mounting the GE-25-P (sides A, B, C)
6.3.3 Screw-in depth and tightening torques - Assembly GE-25-P
For assembly, the following screw-in depths and tightening torques must be
observed.
Item
Fastening the module
GE-25-P
Side A
1
Fastening screw
M3
Max. screw-in depth
7.4 mm
Min. screw-in depth
6.9 mm
Tightening torque
1.2 Nm
2
Centering bushing
Ø 5 mm