Instruction manual for use and maintenance - EN
Rev.: 0
–
aggiornato al 06/11/2020
| Con riserva di modifiche tecniche e salvo errori |
Pag.
19
di
39
-
Use only original replacement filters, as only these filters can guarantee the required filtration
level and are suitable for the unit and its performance.
-
Turn off the unit by the yellow-red main switch.
-
Secure the unit by pulling out the plug from the mains, so that it cannot be accidentally
restarted.
-
Open the inspection door on the side of the unit.
a)
Replacing the cartridge filter
-
Carefully take out the cartridge filter, taking care to avoid any lifting up of dust.
-
To extract it, it is necessary to loosen the 3 screws on the flange.
-
Carefully place the filter in a plastic bag and close it, for example with cable ties.
-
Suitable plastic bags can be supplied by Aerservice Equipments.
-
Insert the new cartridge filter in the special support inside the unit and fasten with the screws.
b)
Replacing the active carbons filter:
-
Open the air grid on the side of the cabinet.
-
Carefully take out the filter avoiding any dust diffusion and close it in a sealed plastic bag.
-
Insert the new filter in the guides behind the grid and fasten again with the screws.
c)
Once the filters have been replaced, proceed as per the following steps:
-
Close the inspection door and check that it is completely closed and that the sealing gasket is
positioned correctly.
-
Reinsert the plug into the mains socket and turn on the yellow-red main switch.
-
Reset alarms as indicated under point 7.4.
-
Dispose of the dirty filters according to the regulations in force locally. Ask the local waste
disposal company for the relevant waste disposal codes.
-
Finally clean the surrounding area, e.g. with an "H" class industrial vacuum cleaner for dust.