Instruction manual for use and maintenance - EN
Rev.: 0
–
aggiornato al 06/11/2020
| Con riserva di modifiche tecniche e salvo errori |
Pag.
13
di
39
6.2.
Control panel
On the front of the unit there is the control panel which is made up of electronic and pneumatic
devices.
Pos. Description
Pos.
Description
1
LED Blower is running
6
ON blower starts
2
LED Filter-cleaning cycle is running
7
OFF blower stops
3
LED Filter clogged
8
Display
4
LED Replace filter
9
Air flow regulator
5
Control panel keys
Below the detailed description:
•
[Position 1.]
After pressing the button ON (pos.6) the signaling LED lights up with a steady green light and
indicates that the electric motor has been powered and is running.
•
[Position 2.]
LED indicator with alternating green light, indicates the start of the cartridge cleaning cycle
using compressed air.
•
[Position 3.]
LED indicator with fixed yellow light, turns on after 600 hours of operation to advise to
perform a check on the filters (if not replaced yet) and a general check on the unit to verify
correct functioning.
•
[Position 4.]
LED indicator with steady red light, lights up when the filter pressure differential gauge
detects a limit pressure difference (data set by the manufacturer) between the dirty air inlet
and the clean air outlet in the filtering section.
•
[Position 5.]
Specific buttons on the control panel to move through the menus and / or modify the
parameters.
•
[Position 6.]
ON key to start extraction - hold for 3s.
•
[Position 7.]
OFF key to switch off extraction - hold for 3s.
•
[Position 8.]
Display showing all information about the pcb.
•
[Position 9.]
Air flow regulator (if provided) to increase or lower the extraction capacity of the unit.
1
2
3
4
5
6
8
7
9