MT-30
Installation, Operation & Maintenance
06225-03H.doc
13 of 47
AeroVironment, Inc
*
1
2
3
4
1
2
3
4
Lower Rear Panel
of Cabinet
*Note: The external switch must be closed to
allow power to be supplied to the system.
Amp P/N:
206430-1
Amp P/N: 206429-1, Connector
Figure 2.8. Remote Emergency Stop
2.2 Technical Specifications
2.2.1 Utility Requirements
Voltage
3-phase, 240 Volts RMS, + 10% / - 15%, < 5% imbalance
(Optional 480Vrms)
Current
130 Amps RMS (65Arms with optional 480Vrms)
Frequency
60 ± 2 Hz (50 +/- 2 Hz optional)
Ground
Connected to chassis
AC Output
Power factor
> 99%
DC Output
Operating range
Configuration
Voltage
Current
Power
Independent A
5 to 120 V
±330 ADC
±30 kW
Independent B
5 to 120 V
±170 ADC
±20 kW
Parallel
5 to 120 V
±500 ADC
±30 kW
The above ranges are the maximum allowed by the system on a continuous basis.
Voltage, the user based on the load and test requirements can set current and
power limits within the above ranges. The maximum continuous power is a
function of the voltage limits. At higher voltages, the peak continuous power is
reduced (see Section 4 for details).
Accuracy
Configuration
Voltage
Current
Resolution
Independent A
± 125 mV or .15%
± 125 mA or .25% of reading
30mV/30mA
Independent B
± 125 mV or .15%
± 50 mA or .25% of reading
30mV/30mA
Parallel
± 125 mV or .15%
± 175 mA or .35% of reading
30mV/30mA
The power accuracy at each point is a simple multiple of the voltage and current
accuracy for that point (with offsets).
Operating Environment