1.1. Environmental Specifications
W A R N I N G : Do not expose this product to environments or conditions outside of the listed
specifications. Exceeding environmental or operating specifications can cause damage to the
equipment.
Table 1-2:
Environmental Specifications
Ambient
Temperature
Operating: 10° to 35° C (50° to 95° F)
The optimal operating temperature is 20° C ±2° C (68° F ±4° F). If at any time the
operating temperature deviates from 20° C, degradation in performance could occur.
Storage: 0° to 40° C (32° to 104° F) in original shipping packaging
Humidity
Operating: 40% to 60% RH
The optimal operating humidity is 50% RH.
Storage: 30% to 60% RH, non-condensing in original packaging. The stage should be
packaged with desiccant if it is to be stored for an extended time.
Altitude
Operating: 0 m to 2,000 m (0 ft to 6,562 ft) above sea level
Contact Aerotech if you need to use your equipment in a location that is 2,000 m above
or below sea level.
Vibration
Use the system in a low vibration environment. Excessive floor or acoustical vibration
can affect system performance. Contact Aerotech for information regarding your spe-
cific application.
Protection
Rating
The LaserTurn
®
1 stages have limited protection against dust, but not water. This
equates to an ingress protection rating of IP50.
Use
Indoor use only
1.2. Accuracy and Temperature Effects
Extreme temperature changes could cause a decrease in performance or permanent damage to the stage.
Aerotech stages are designed for and built in a 20°C (68°F) environment. Any deviation from standard
operating temperature will affect stage accuracy. The severity of temperature effects on all stage
specifications depends on many different environmental conditions, including how the stage is mounted.
Contact the factory for more details.
10
Chapter 1
www.aerotech.com
Содержание LaserTurn 1 Series
Страница 1: ...Revision 1 07 00 LaserTurn 1 Hardware Manual ...
Страница 8: ...Table of Contents LaserTurn 1 Hardware Manual 8 www aerotech com This page intentionally left blank ...
Страница 12: ...Overview LaserTurn 1 Hardware Manual 12 Chapter 1 www aerotech com This page intentionally left blank ...
Страница 52: ...Maintenance LaserTurn 1 Hardware Manual 52 Chapter 4 www aerotech com This page intentionally left blank ...
Страница 56: ...Revision History LaserTurn 1 Hardware Manual 56 Appendix B www aerotech com This page intentionally left blank ...