DR500 Operation and Technical Manual
Set Up
Version 1.6
Aerotech, Inc.
2-25
Table 2-16.
AS32020 / AS32030 Series Electrical Specifications
Units
AS32020
AS32030
Peak Current Output (2 sec)
Amps
±20 ±30
Continuous Output Current
Amps
±7
±10.7
Output Fuse, F1 (3 AG, slow blow)
Amps
8
12
Peak Output Voltage
Volts
160*
160*
Efficiency %
93
Power Amplifier
Gain (continuous output)
Amps/Volt
1
2
PWM Switching Frequency
kHz
20
Output Current Limit
Amps (max)
Adjustable: Zero to Peak
Shutdown Input
Tristates Motor Output
Minimum Load Inductance
mH
2
Operating Temperature
°C
0 to 50
Storage Temperature
°C
-30 to 85
Weight kg
(lb)
0.5
(1)
* 320VDC, but limited by internal bus power supply to 160VDC.
Table 2-17.
AS32020/AS32030 Series Test Points
Test Point
Signal
TP4 Common
TP5 +5V
TP6
Phase A Current Command
TP7
Phase B Current Command
TP8
Phase B Feedback
TP9
Phase A Feedback
DS1
LED Drive Enable