![Aerotech Automation1 XL2e Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/aerotech/automation1-xl2e/automation1-xl2e_hardware-manual_2863031049.webp)
Table 2-25:
STO Electrical Specifications
Status
Value
STO off (motion allowed)
18-24 V, 7 ma
STO on (safe state entered, no motion)
0-6 V
Recommended Wire Gauge
22-26 AWG (0.5 - 0.14 mm
2
)
STO System Power Supply
PELV
STO Wire Length (maximum)
50 m
shows one safety device connected to multiple drives in parallel.
WARNING
: The drive does not check for short circuits on the external STO wiring. If this
is not done by the external safety device, short circuits on the wiring must be excluded.
Refer to EN ISO 13849-2. For Category 4 systems, the exclusion of short circuits is
mandatory.
Figure 2-24:
Typical STO Configuration
XL2e Hardware Manual
2.4. Safe Torque Off Input (STO)
www.aerotech.com
49
PENDING
Содержание Automation1 XL2e
Страница 1: ...Revision 1 01 Automation1 XL2e High Performance Linear Digital Drive HARDWARE MANUAL...
Страница 12: ...This page intentionally left blank Agency Approvals XL2e Hardware Manual 12 www aerotech com P E N D I N G...
Страница 22: ...1 2 2 Dimensions Figure 1 3 Dimensions 1 2 2 Dimensions XL2e Hardware Manual 22 www aerotech com...
Страница 23: ...Figure 1 4 Dimensions EB1 XL2e Hardware Manual 1 2 2 Dimensions www aerotech com 23...
Страница 71: ...Figure 3 11 Digital Outputs Schematic EB1 XL2e Hardware Manual 3 4 Digital Outputs EB1 www aerotech com 71...
Страница 82: ...This page intentionally left blank 5 2 Fuse Specifications XL2e Hardware Manual 82 www aerotech com...
Страница 86: ...This page intentionally left blank Appendix B Revision History XL2e Hardware Manual 86 www aerotech com...
Страница 92: ...Index XL2e Hardware Manual This page intentionally left blank 92 www aerotech com...