RN200 Mono Software User Manual
13
3.2.2
Active/Signaling RF test with test instrument
An example of active/signaling RF test setup with an external test instrument is shown in
Figure 9: Active/ signaling RF test system diagram (with test instrument)
Cables connection instructions:
1.
Connect both device’s LAN port and VNA’s LAN port to a network switch; then connect
the control PC to the network switch with an RJ45 cable.
2.
Use a USB cable, and connect the device’s USB Type-B port on the interface panel with a
USB port on the control PC.
3.
Connect the uplink/downlink signal of the wireless tester/instrument to the SPDT (RF
switch) and connect the two output ports of SPDT to the H and V ports of the RN200.
4.
Connect communication signal from wireless tester/instrument to the CA port of the
RN200 directly.
Note: When using the external instruments, users must prepare the test instrument and SPDT,
and program the test software by themselves.
3.2.3
Active/non-signaling RF test with test instrument
An example of active/non-signaling RF test setup with an external test instrument is shown