5.0 PREVENTATIVE MAINTENANCE
The mRDS must be flushed with distilled water on a monthly basis to ensure proper operation and a long
life. The length of time necessary to fully flush the system is dependent on the number of nozzles installed
inside the treatment area. After flushing the system, you should re-prime the system by switching the reservoir
back to Vital-Oxide and running for the prescribed time. Please refer to Table 1 for Flush and Re-Prime
times. You must follow the following steps flush the system correctly.
5.1 General Guidelines
5.1.1
Flush mRDS completely on a monthly basis.
5.1.2
Use
only
distilled or deionized water when flushing the mRDS.
5.1.3
After the maintenance flush, re-prime the mRDS with disinfectant
5.2 Maintenance Steps
5.2.1
Replace on-board operating reservoir with the provided maintenance reservoir.
5.2.2
Ensure that the maintenance reservoir is filled with
distilled or deionized water only
.
5.2.2
Start the operation of the mRDS unit like normal.
5.2.3
Use the Touchscreen Controller as an E-stop to stop the unit after it has run for the
prescribed Flush Time (see Table 1).
5.2.4
Reset the system.
5.2.5
Replace the on-board operating reservoir filled with Vital-Oxide
5.2.6
Start the operation of the mRDS unit like normal.
5.2.7
Use the Touchscreen Controller as an E-stop to stop the unit after it has run for the prescribed
Re-Prime Time (see Table 1).
5.2.8
Reset the system.
Table 1
System
Flush Time
Re-Prime Time
mRDS
4 minutes
3 minutes