ROOM DECONTAMINATION SYSTEM 

OPERATOR MANUAL 

 

Model(s): mRDS 

This document contains information which is proprietary to AeroClave, LLC. Accordingly, the infor-
mation in this document shall not be disclosed outside the customer’s organization and shall not be 
duplicated, used or disclosed – in whole or in part – for any purpose other than to evaluate this infor-
mation. This restriction does not limit the customer’s right to use information contained in this docu-
ment if it is obtained from another source without restriction. The data subject to this restriction are 
contained in all sheets of this document. 

 

This technical data is controlled under the Export Administration Regulations, and may not be exported 
to a Foreign Person, either in the U.S. or abroad, without the proper authorization of the U.S. Depart-
ment of Commerce.

 

Содержание mRDS

Страница 1: ...y purpose other than to evaluate this infor mation This restriction does not limit the customer s right to use information contained in this docu ment if it is obtained from another source without restriction The data subject to this restriction are contained in all sheets of this document This technical data is controlled under the Export Administration Regulations and may not be exported to a Fo...

Страница 2: ... 1 3 Equipment and Media 3 2 0 SAFETY GUIDELINES 4 2 1 Operational Safety Guidelines 4 2 2 Operator Qualification 5 3 0 PRODUCT DESCRIPTION 6 3 1 Technical Specifications 6 4 0 SET UP OPERATION 6 4 1 Pre decontamination Set up 6 4 2 Decontamination Cycle Start 7 4 3 Decontamination Cycle Operation 9 4 4 Emergency Stop Operation 13 5 0 PREVENTATIVE MAINTENANCE 15 5 1 General Guidelines 15 5 2 Maint...

Страница 3: ...osolized and applied evenly to the treatment area A typical injection phase can last anywhere from 5 30 minutes depending on the size of the treatment area Dwell Phase Once an injection phase has completed the treatment area is allowed to sit for a minimum of 10 minutes in a dwell period The dwell period gives the aerosolized solution an opportunity to evenly distribute throughout the treatment ar...

Страница 4: ...nderstand this document b mRDS Operator Training individuals who will be operating the mRDS unit for facility or asset decontamination using AeroClave solution must be trained and qualified See the requirements in Section 2 2 Operator Qualifications 2 1 3 Only an authorized AeroClave service technician may repair or maintain this equipment 2 1 4 The mRDS unit is designed to operate on a standard 1...

Страница 5: ...roClave approved solutions for decontamination Use of other solutions poses risk of injury machine failure and or unintended results and is prohibited 2 1 13 Use only de ionized or distilled water to flush demonstrate or practice with the system 2 1 14 Prior to transport or storage of the machine remove solution tank and transport or store separate from machine 2 1 15 Read and understand the AeroC...

Страница 6: ...and windows have been properly shut c That any and all items not wished to be decontaminated have been removed from the treatment area d That all surfaces wishing to be decontaminated are exposed e g open drawers and cabinet doors 4 1 2 Adequately isolate area by shutting down and or close off all HVAC ventilation or exhaust 4 1 3 Once the treatment area has been deemed safe exit the area being su...

Страница 7: ...2 These steps describe the process involved with initiating a decontamination cycle but do NOT include information regarding operation during a decontamination cycle 4 2 3 Only verified operator s may access and operate the mRDS from the touchscreen controller 4 2 4 The Touchscreen Controller is used to monitor and control the mRDS through all phases of its operation 4 2 5 Activate the mRDS by pre...

Страница 8: ...d on this sheet is subject to the restriction on the cover page of this User s Manual 4 2 6 Upon initial activation a safety prompt will appear Figure 2 4 2 7 Once criteria on the safety prompt have been met tap the green start button to begin the decontamination process Figure 3 FIGURE 2 FIGURE 3 ...

Страница 9: ...be the process and screens regarding operation DURING a decontamination cycle 4 3 3 The touchscreen controller is used to monitor and control the mRDS through all phases of its operation 4 3 4 Activate the mRDS by following the steps described in Section 4 2 4 3 5 Prior to the start of the decontamination process the system will cycle through an initial warning stage 4 3 6 This Warning Countdown s...

Страница 10: ...ser s Manual 4 3 8 The first stage of the decontamination process is the Injection stage This is when the disinfectant solution is atomized into the treatment area Figure 5 4 3 9 The second stage of the decontamination process is the 10 minute Dwell stage This is when the disinfectant solution achieves the necessary surface contact time Figure 6 FIGURE 5 FIGURE 6 Dwell ...

Страница 11: ...age is the Aeration stage This is when ventilation of the treatment area occurs to return the environment to normal operating conditions During this stage normal operation of HVAC exhaust or ventilation can resume Figure 7 4 3 11 The Touchscreen Controller will switch from red to yellow to green as the Aeration stage and the decontamination process finishes Figure 8 FIGURE 8 Aeration Aeration FIGU...

Страница 12: ... this sheet is subject to the restriction on the cover page of this User s Manual 4 3 12 Once the Touchscreen Controller has returned to the green SAFE TO ENTER screen AND the air in the treatment area is clear it is safe to resume normal operation and habitation of the treatment area Figure 9 FIGURE 9 ...

Страница 13: ...tion 4 4 2 These steps describe the process and screens regarding emergency stop operation DURING a decontamination cycle 4 4 3 The mRDS emergency stop procedure initiates a total shutdown of the system 4 4 4 To initiate an emergency stop simply press the red Emergency Stop bar at the bottom of the Touchscreen Controller Figure 10 4 4 5 Once an emergency stop has been initiated determine the reaso...

Страница 14: ...this User s Manual 4 4 6 Once the situation has been resolved reset the mRDS by pressing the Reset button on the bottom left corner of the Touchscreen Controller prior to operation Figure 11 4 4 7 Upon pressing Reset the Touchscreen Controller will return to the green SAFE TO ENTER screen At this point operation of the mRDS can resume Figure 12 FIGURE 11 FIGURE 12 ...

Страница 15: ...s 5 1 1 Flush mRDS completely on a monthly basis 5 1 2 Use only distilled or deionized water when flushing the mRDS 5 1 3 After the maintenance flush re prime the mRDS with disinfectant 5 2 Maintenance Steps 5 2 1 Replace on board operating reservoir with the provided maintenance reservoir 5 2 2 Ensure that the maintenance reservoir is filled with distilled ordeionized wateronly 5 2 2 Start the op...

Страница 16: ...ed with each stage of the decontamination process can be adjusted if necessary by accessing the Configuration screen NOTE Do NOT adjust these values without first consulting with authorized AeroClave personnel 6 1 2 To access the Configuration screen press the Install button on the bottom right corner of the Touchscreen Controller Figure 13 6 1 3 Tap the white dialog boxes to input the time for ea...