background image

4

1. 

REMOTE CONTROL

• 

Some  of the buttons of the re-

mote control are not used for the 

required air conditioner and are 

therefore not described in these in-

structions. Pressing of these keys will 

not affect the operation of the air 

conditioner.

• 

Check  there are no obstructions 

between the receiver and the re-

mote control.

• 

The  maximum distance between 

the IR receiver and the remote 

control is 8 metres, to ensure the 

signal is correctly received.

• 

Position the remote control at least 

1 metre away from TVs, radios, ste-

reos, etc. There may be some au-

dio and video interference.

• 

Do not drop or throw the remote 

control.

• 

Do not let liquids enter the remote 

control, and do not leave it in di-

rect sunlight or in hot places.

• 

When  the remote control sends a 

signal the symbol   appears on 

the display, the receiver of the in-

door unit emits a sound to confirm 

reception of the signal.

3

1

Index Function of the button:

1

Operating mode selection

2

Switches the unit on or off

3

Sets the fan speed

4

Sets the operation of the motorised air discharge fin (swing function)

5

Increases value (operating setpoint, timer, etc.)

6

Activates or deactivates the maximum fan speed (TURBO)

7

Activates or deactivates the SLEEP function (this function is applicable to the cooling and heating modes). Once 

activated this function will control the unit in order to maintain an ideal temperature (this temperature is automatically 

calculated and cannot be set)

8

Decreases value (operating setpoint, timer, etc.)

9

It displays in the indoor unit’s monitor the set temperature and the room air temperature (or the external air temperature)

10

Sets the time on the system clock

11

Activates or deactivates the WIFI card (available with accessory WIFIKIT/WIFIKIT10)

12

Activates or deactivates the display of information of the indoor unit

13

Activates, deactivates or changes the programmed switch on timer

14

Activates, deactivates or changes the programmed switch off timer

Keys available 

on remote control

6

4

9

7

10

14

2

5

8

11

12

13

Содержание WLRC10

Страница 1: ...USER MANUAL WLRC10 REMOTE CONTROLLER 18 06 5044571_01 ...

Страница 2: ......

Страница 3: ...ta may undergo modifications considered necessary for the improvement of the product at any time and without the obligation for any notice thereof Thank you once again AERMEC S p A INFRARED REMOTE CONTROL CORRECT BATTERY DISPOSAL INFORMATION FOR CORRECT BATTERY DISPOSAL PURSUANT TO EUROPEAN DIRECTIVE 2006 66 EC Please replace the coil when its electric charge is exhausted at the end of its shelf l...

Страница 4: ...he button 1 Operating mode selection 2 Switches the unit on or off 3 Sets the fan speed 4 Sets the operation of the motorised air discharge fin swing function 5 Increases value operating setpoint timer etc 6 Activates or deactivates the maximum fan speed TURBO 7 Activates or deactivates the SLEEP function this function is applicable to the cooling and heating modes Once activated this function wil...

Страница 5: ... 13 Indicates the TURBO function is active the fan speed is forced by this function 14 Indicates the setting has been transmitted to the receiver located on the indoor unit 15 Indicates that the anti freeze function is activated set temperature 8 C 16 Indicates the extended ventilation function is active only in cooling or dehumidification 17 Not available 18 Not available 19 Indicates the operati...

Страница 6: ...ion Heating The various operating modes have different features and ranges AUTOMATIC mode in this mode no setpoint value is dis played on the remote control and the fan speed setting is AUTO as default During the AUTOMATIC mode the unit calculates whether to cool room temperature 25 C heat room temperature 23 C or just ventilate room temperature between 23 C and 25 C COOLING mode in this mode the ...

Страница 7: ...point the unit is switched on until the room temperature rises above the setpoint value SETTING THE OPERATING SETPOINT All the operating modes except the automatic one require an room air temperature value to control to this is called the operating setpoint If the unit is on and the automatic mode is not selected pressing the and buttons allows decreasing or in creasing the operating setpoint The ...

Страница 8: ...tton it activates the swing of the motorized supply air fin The fin allows to change the air flow in the room depending on the set position The logic where this function is managed When the unit is on while pressing the button it s possible to set one by one the following steps Motorised discharge fin setting Fluctuation continues Fixed Step 1 Fixed Step 2 Fixed Step 3 Fixed Step 4 Fixed Step 5 Ar...

Страница 9: ...OGRAMMED SWITCH OFF TIMER OFF The units possess a timer used to program switching off by specifying the time that you want the unit to deactivate If the unit is switched off and no other programmed switch off times are present by pressing the key you enter the time programming mode in this mode the OFF icon to the right of the time flashes and by pressing the keys and it is possible to set the swi...

Страница 10: ...n deactivates automatically NOTE Once a programmed switch on is set the operating mode the working setpoint and fan speed will be the same as those present when the unit stops Setting a programmed switch on ACTIVATING DEACTIVATING THE EXTENDED VENTILATION During the operation in cooling or dehumidification mode the condensate caused by the humidity in the air is formed on the heat exchanger within...

Страница 11: ...isplay on the indoor unit s display is the operating setpoint the room temperature value is displayed for 3 seconds after which the display re turns to the operating setpoint To display the room temperature again it is necessary to select the cor responding symbol on the remote control On some models there is no external air reading in these cases the working set will be displayed again ACTIVATING...

Страница 12: ...lth function If the function is active the icon is dis played on the remote control NOTE The night time health function is deactivated by switching off the unit and on restarting will not be active this func tion can be activated at any time Setting night time comfort function ACTIVATING DEACTIVATING THE INDOOR UNIT S DISPLAY The display on the indoor unit must be activated using the remote contro...

Страница 13: ...ay shows that the keypad of the remote control is locked Setting the button lock SETTING THE UNIT OF MEASUREMENT The unit can display the temperature values in C or in F To change the unit of measurement simultaneously press the and buttons with the unit switched off The temper ature value on the remote control s display is automatically converted Setting the unit of measurement ...

Страница 14: ...e remote controller is placed near the user within the maximum distance of 8 meters During this function is it recommended to keep the remo te away from heating sources that could change the real room temperature reading Setting the anti freeze function ACTIVATING DEACTIVATING THE IFEEL FUNCTION The IFEEL function uses a temperature probe inside the infra red remote control in order to comunicate ...

Страница 15: ...he accessory WIFIKIT WIFIKIT10 has been planned to activate or deactivate the WIFI function press the button the display shows the icon indicating that the function is now active ACTIVATE OR DEACTIVATE THE WIFI FUNCTION ATTENTION in order to use this function it s MANDATORY to install in the unit the specific accessory WIFIKIT WIFIKIT10 ...

Страница 16: ...ity 4 Close the battery cover NOTE When batteries are replaced use new batteries of the recommended type Remove the batteries if the remote control is not used for extended periods The remote control can emit a signal up to a maxi mum distance of 7 metres The unit can be affected by signals transmitted by remote controls for televisions video recorders or other devices used in the same room WARNIN...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...ilacqua VR Italia Tel 39 0442 633111 Fax 39 0442 93577 marketing aermec com www aermec com Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data ...