background image

INFORMATION FOR USER

This device is universal.

By pressing a key for a function that is not available, the unit will not change the operating status. 

Never install the device in a damp area and do not expose it to direct sunlight.

Do not bump, throw or disassemble the device frequently.

Never use the device with wet hands.

Carefully read the manual before using and installing the device.

Dear customer,

Thank you for choosing an AERMEC product. It is the fruit of many years of 

experience and special design studies and has been made of the highest grade 

materials and with cutting edge technology.

In addition, all our products bear the EC mark indicating that they meet the 

requirements of the European Machine Directive regarding safety. The quality level 

is being constantly monitored, so AERMEC products are synonymous with Safety, 

Quality and Reliability.

The

 

data may undergo modifications considered necessary for the improvement of 

the product, at any time and without the obligation for any notice thereof.

Thank you once again.

AERMEC S.p.A

INFRARED REMOTE CONTROL – CORRECT BATTERY DISPOSAL 

INFORMATION FOR CORRECT BATTERY DISPOSAL PURSUANT TO EUROPEAN DIRECTIVE 2006/66/EC

Please replace the coil when its electric charge is exhausted: at the end of its shelf life, this battery must not be 

disposed of together with separate waste.

It must be delivered to special collection centres or to dealers that provide this service. Disposing of a battery se-

parately avoid possible negative effects on the environment and on human health caused by inadequate dispo-

sal and allows recovering and recycling the composing material, with significant savings of energy and resources.

To underline the obligation to dispose of the batteries separately, the crossed bin symbol is shown on the battery. 

Illegal disposal of the product by the user involves the application of administrative sanctions provided for by the 

current legislation.

Содержание WLRC10

Страница 1: ...USER MANUAL WLRC10 REMOTE CONTROLLER 18 06 5044571_01 ...

Страница 2: ......

Страница 3: ...ta may undergo modifications considered necessary for the improvement of the product at any time and without the obligation for any notice thereof Thank you once again AERMEC S p A INFRARED REMOTE CONTROL CORRECT BATTERY DISPOSAL INFORMATION FOR CORRECT BATTERY DISPOSAL PURSUANT TO EUROPEAN DIRECTIVE 2006 66 EC Please replace the coil when its electric charge is exhausted at the end of its shelf l...

Страница 4: ...he button 1 Operating mode selection 2 Switches the unit on or off 3 Sets the fan speed 4 Sets the operation of the motorised air discharge fin swing function 5 Increases value operating setpoint timer etc 6 Activates or deactivates the maximum fan speed TURBO 7 Activates or deactivates the SLEEP function this function is applicable to the cooling and heating modes Once activated this function wil...

Страница 5: ... 13 Indicates the TURBO function is active the fan speed is forced by this function 14 Indicates the setting has been transmitted to the receiver located on the indoor unit 15 Indicates that the anti freeze function is activated set temperature 8 C 16 Indicates the extended ventilation function is active only in cooling or dehumidification 17 Not available 18 Not available 19 Indicates the operati...

Страница 6: ...ion Heating The various operating modes have different features and ranges AUTOMATIC mode in this mode no setpoint value is dis played on the remote control and the fan speed setting is AUTO as default During the AUTOMATIC mode the unit calculates whether to cool room temperature 25 C heat room temperature 23 C or just ventilate room temperature between 23 C and 25 C COOLING mode in this mode the ...

Страница 7: ...point the unit is switched on until the room temperature rises above the setpoint value SETTING THE OPERATING SETPOINT All the operating modes except the automatic one require an room air temperature value to control to this is called the operating setpoint If the unit is on and the automatic mode is not selected pressing the and buttons allows decreasing or in creasing the operating setpoint The ...

Страница 8: ...tton it activates the swing of the motorized supply air fin The fin allows to change the air flow in the room depending on the set position The logic where this function is managed When the unit is on while pressing the button it s possible to set one by one the following steps Motorised discharge fin setting Fluctuation continues Fixed Step 1 Fixed Step 2 Fixed Step 3 Fixed Step 4 Fixed Step 5 Ar...

Страница 9: ...OGRAMMED SWITCH OFF TIMER OFF The units possess a timer used to program switching off by specifying the time that you want the unit to deactivate If the unit is switched off and no other programmed switch off times are present by pressing the key you enter the time programming mode in this mode the OFF icon to the right of the time flashes and by pressing the keys and it is possible to set the swi...

Страница 10: ...n deactivates automatically NOTE Once a programmed switch on is set the operating mode the working setpoint and fan speed will be the same as those present when the unit stops Setting a programmed switch on ACTIVATING DEACTIVATING THE EXTENDED VENTILATION During the operation in cooling or dehumidification mode the condensate caused by the humidity in the air is formed on the heat exchanger within...

Страница 11: ...isplay on the indoor unit s display is the operating setpoint the room temperature value is displayed for 3 seconds after which the display re turns to the operating setpoint To display the room temperature again it is necessary to select the cor responding symbol on the remote control On some models there is no external air reading in these cases the working set will be displayed again ACTIVATING...

Страница 12: ...lth function If the function is active the icon is dis played on the remote control NOTE The night time health function is deactivated by switching off the unit and on restarting will not be active this func tion can be activated at any time Setting night time comfort function ACTIVATING DEACTIVATING THE INDOOR UNIT S DISPLAY The display on the indoor unit must be activated using the remote contro...

Страница 13: ...ay shows that the keypad of the remote control is locked Setting the button lock SETTING THE UNIT OF MEASUREMENT The unit can display the temperature values in C or in F To change the unit of measurement simultaneously press the and buttons with the unit switched off The temper ature value on the remote control s display is automatically converted Setting the unit of measurement ...

Страница 14: ...e remote controller is placed near the user within the maximum distance of 8 meters During this function is it recommended to keep the remo te away from heating sources that could change the real room temperature reading Setting the anti freeze function ACTIVATING DEACTIVATING THE IFEEL FUNCTION The IFEEL function uses a temperature probe inside the infra red remote control in order to comunicate ...

Страница 15: ...he accessory WIFIKIT WIFIKIT10 has been planned to activate or deactivate the WIFI function press the button the display shows the icon indicating that the function is now active ACTIVATE OR DEACTIVATE THE WIFI FUNCTION ATTENTION in order to use this function it s MANDATORY to install in the unit the specific accessory WIFIKIT WIFIKIT10 ...

Страница 16: ...ity 4 Close the battery cover NOTE When batteries are replaced use new batteries of the recommended type Remove the batteries if the remote control is not used for extended periods The remote control can emit a signal up to a maxi mum distance of 7 metres The unit can be affected by signals transmitted by remote controls for televisions video recorders or other devices used in the same room WARNIN...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...ilacqua VR Italia Tel 39 0442 633111 Fax 39 0442 93577 marketing aermec com www aermec com Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data ...

Отзывы: