![AERMEC NRL Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/aermec/nrl/nrl_technical-manual-installation-maintenance_2861924016.webp)
16
INRLPY. 02.10 4086916_01
2800
3000
3300
3600
HIGH-HEAD CIRCULATION PUMP
Input power
KW
H
17.2
17.2
24.7
24.7
HL
Input current
A
H
29.2
29.2
42.4
42.4
HL
Useful head on cooling
kPa
H
290
274
257
251
HL
310
297
280
276
Useful head on heating
kPa
H
239
210
225
214
HL
SOUND DATA
Sound power (1)
dBA
H
94.0
93.5
95.0
97.0
HL
91.0
90.5
92.0
94.0
Sound pressure (2)
dBA
H
62.0
61.5
63.0
65.0
HL
59.0
58.5
60.0
62.0
DIMENSIONS
Height
mm
H
2450
2450
2450
2450
HL
Width
mm
H
2200
2200
2200
2200
HL
Depth
mm
H
8100
8100
8100
8100
HL
Weight when empty
kg
H
6080
6490
6660
6880
HL
2800
3000
3300
3600
LOW-HEAD CIRCULATION PUMP
Input power
KW
H
9.6
13.0
13.0
13.0
HL
Input current
A
H
16.3
22.0
22.0
22.0
HL
Useful head on cooling
kPa
H
149
142
122
115
HL
167
157
145
141
Useful head on heating
kPa
H
104
104
88
77
HL
(1) Sound power
Aermec determines the sound power value on the basis of measurements
taken in accordance with standard 9614-2, in compliance with the Eurovent
certi
fi
cation.
(2) Sound pressure
Sound pressure in an unrestricted range on a re
fl
ective plane (directional fact.
Q=2), 10m away from the unit external surface, complying with ISO 3744.
EVAPORATORS (PLATES)
Quantity
no.
H
2
2
2
2
HL
Water connections (in/out)*
diam
H
4"
4"
4"
4"
HL
HYDRAULIC CIRCUIT
Accumulator capacity
L
H
2 x 700
HL
Accumulator antifreeze heater
W
H
2 x 300
HL
Expansion tank capacity
No./l
A
4 x 25
E
NOMINAL REFERENCE CONDITIONS
COOLING MODE
- Inlet water temperature
12°C
- Outlet water temperature
7°C
- Outside air temperature
35°C
-
Δ
t 5°C
HEATING mode
- Inlet water temperature
40°C
- Outlet water temperature
45°C
- Outside air temperature
7/6°C
-
Δ
t 5°C