WARNING
Please read this manual carefully before using the 
unit.

WARNING
Please read this manual carefully before installing 
the unit.

WARNING
Please read this manual carefully before repairing 
or performing maintenance on the unit.

WARNING
This unit contains flammable R32 gas.

• 

The FK unit uses eco-friendly R32 coolant gas. 

• 

The coolant gas is odourless.

• 

R32 coolant gas is flammable, but only in the presence of flames.

• 

There is a chance of explosion but only if a certain concentration is 

reached in the air.

• 

Smoking near the unit is prohibited.

• 

Provide signage prohibiting smoking near the unit.

• 

The flammability of the gas is very low. 

• 

Keep the room where the unit is installed well ventilated.

• 

Do not pierce or burn the unit.

• 

The unit cannot be placed near ignition sources such as open 

flames, electric heaters, etc. 

• 

All repairs or extraordinary maintenance operations must be carried 

out by specialised technicians or qualified personnel.

1. 

WARNINGS

1.1. 

GENERAL WARNINGS

1.2. 

WARNINGS FOR R32 COOLANT GAS

1.3. 

R32 GAS ADVANTAGES

• 

Compared to common coolants, R32 is a non-polluting coolant. 

It causes no damage to the ozone layer and does not add to the 

greenhouse effect..

• 

R32 has excellent thermodynamic features that lead to high energy 

efficiency.

1.4. 

WARNINGS FOR MAINTENANCE OR REPAIR

 

THESE PROCEDURES MAY ONLY BE FOLLOWED BY SPECIALISED 

TECHNICIANS OR QUALIFIED PERSONNEL.

 If 

the pipes of the coolant system are to be cut or welded, please 

follow the steps below: 

 1. 

Turn off the unit and disconnect it from the electricity

 2. 

Drain the coolant gas 

 3. 

Extract the remaining gas

 4. 

Clean with Nitrogen (N2)

 5. 

The pipes can only be cut or welded at this moment

 6. 

Ensure that there are not open flames

 7. 

The coolant must be recycled in the special tanks

1.5. 

FILLING R32 COOLANT GAS

 THESE 

PROCEDURES MAY ONLY BE FOLLOWED BY SPECIALISED 

TECHNICIANS OR QUALIFIED PERSONNEL.

• 

Make sure that other types of coolant do not contaminate the R32.

• 

The gas tank must be kept in a vertical position during filling.

• 

Apply the specified label to the unit after filling.

• 

Do not add more coolant gas than necessary.

• 

Once filling is finished, carry out the leak detection operations 

before testing its functioning.

• 

A second check for gas leaks must be performed once all of the 

previous operations are completed.

1.6. 

DISPOSAL OF R32 COOLANT GAS

 THESE 

PROCEDURES MAY ONLY BE FOLLOWED BY SPECIALISED 

TECHNICIANS OR QUALIFIED PERSONNEL.

• 

Do not dispose of it in areas with a risk of formation of explosive 

atmospheres with the air. The gas must be disposed of in a suitable 

torch with an anti-flame-return device. Contact the supplier if you 

need instructions for use.

1.7. 

SAFETY STANDARDS FOR TRANSPORTATION AND STORAGE

• 

Using a suitable gas detector, check that there are no gas leaks in 

the environment before draining, and open the container of the 

unit.

• 

Ensure there are no ignition sources near the unit.

• 

Smoking near the unit is prohibited.

WARNING

Do not use means to accelerate the defrosting process or to clean, 

other than those recommended by the manufacturer.

Should repair be necessary, contact your nearest authorized Service Centre.

Any repairs carried out by unqualified personnel may be dangerous.

The appliance must be stored in a room without continuously operating 

ignition sources (for example: open flames, an operating gas appliance or an 

operating electric heater). Do not pierce or burn.

Appliance must be installed, operated and stored in a room with a floor area 

larger than X m². (Please see below table).

Appliance filled with flammable gas R32. For repairs, refer to manufacturer’s 

instructions only.

Be aware that refrigerants do not contain odour. Read specialist’s manual.

Minimum room 

area m

2

 

Charge amount “kg”

≤1,2 1,3

1,4

1,5

1,6

1,7

1,8

1,9

2

2,1

2,2

2,3

2,4

2,5

window mounted

-

5,2

6,1

7

7,9

8,9

10

11,2 12,4 13,6

15

16,3 17,8 19,3

Содержание FK260

Страница 1: ...EN USE AND INSTALLATION MANUAL Aermec 16 01 5140901_01 FK260 FK360 Energy efficiency A 5140901_01...

Страница 2: ...NS FOR INSTALLATION OF THE UNIT 10 7 2 POSITIONING 10 7 3 MINIMUM TECHNICAL CLEARANCES 11 7 4 CONDENSATE DRAINAGE 11 7 5 ELECTRICAL WARNINGS 12 7 6 UNIT DIMENSIONS 12 8 WIRING DIAGRAMS 13 9 OPERATING...

Страница 3: ...laws All specifications are subject to change without prior notice Although every effort has been made to ensure precision Aermec does not assume any responsibility for any errors or omissions Dear c...

Страница 4: ...Y ONLY BE FOLLOWED BY SPECIALISED TECHNICIANS OR QUALIFIED PERSONNEL Make sure that other types of coolant do not contaminate the R32 The gas tank must be kept in a vertical position during filling Ap...

Страница 5: ...s Service these operations must only be carried out by Personnel with the specific technical skills Ensure that the power supply and the installed output are adequately scaled to supply the air condit...

Страница 6: ...cally check that the installation conditions of the unit have not been altered and have the system checked by a qualified engineer Do not remove the protection grilles Do not insert your hands or any...

Страница 7: ...remote control Control panel on the machine Compact unit with reduced dimensions Three possible functions Cooling Dehumidification Ventilation only Class A energy efficiency Contained sound emissions...

Страница 8: ...enser attachment diameter mm 7 7 Fan Type Axial Axial Air flow rate m3 h 800 1200 Sound pressure maximum dB A 56 58 Sound pressure medium dB A 54 56 Sound pressure minimum dB A 52 54 Sound power maxim...

Страница 9: ...9 Aermec 16 01 5140901_01 6 DESCRIPTION OF COMPONENTS Inner side Air filter Outer side...

Страница 10: ...the air delivery and intake sockets in the internal part so that air can circulate freely Ensure the installation complies with the minimum technical clearances specified in the installation diagram...

Страница 11: ...re starting up the unit Slide the frame of the unit from the base Install the drainage tub on the corner and fix it with two screws as shown in the figure Connect the drainage pipe NOT provided to the...

Страница 12: ...Ensure that the earthing cable is connected to the building s earthing connection system Ensure that a differential switch suitable for leaks to the ground is installed Do not connect the earth cable...

Страница 13: ...tilator PE W V U N AC L AP1 BN M BU YEGN BU YE RD Kompressor CN1 W V U YEGN 2 XT 1 berstrom ausl ser RD RD WARNUNG 15K 50K 20K CN3 RT1 RT2 RT3 WH BK Temp F hler Lufteintritt Temp F hler Register Temp...

Страница 14: ...e or generate noise Has a check for refrigerant leaks been performed Poor performance Is the thermal insulation sufficient It could cause condensate and dripping water Does the unit correctly drain th...

Страница 15: ...hese steps the filter is still dirty fill a tub with lukewarm water and some non aggressive cleanser and soak it for a few minutes Next dry it with a cloth 5 Otherwise have a specialised technician cl...

Страница 16: ...to select the fan speed 5 SWING button Press this button to select the fan mode from left to right 6 TIMER button Timer function for setting the time the unit is switched on or off Temp function to se...

Страница 17: ...d FAN Ventilation only mode the unit operates in ventilation mode In this case press the FAN button repeatedly to adjust the ventilation speed 3 button Function 1 Pressing or once will increase or red...

Страница 18: ...GRAMMED START UP FUNCTION When the unit is turned off pressed the Timer button to set the programmed start up function The T ON and H icons on the display will start to blink In 5 seconds press the bu...

Страница 19: ...careful not to invert the polarity Close the battery cover NOTE When batteries are replaced use new batteries of the recommended type Remove the batteries if the remote control is not used for extende...

Страница 20: ...room temperature We recommend that you do not keep the air jets direct instead set the unit to Swing mode Make sure the doors and windows are closed well Avoid opening the doors and windows of the roo...

Страница 21: ...ssor protection from overloading Contact specialised personnel or the Aermec Assistance Service L9 Power supply protection Contact specialised personnel or the Aermec Assistance Service H5 Module temp...

Страница 22: ...suggested by the producer of the material The unit must be installed in a space that respects the minimum allowed dimensions Please carefully observe the following table Verify that the maintenance ar...

Страница 23: ......

Страница 24: ...le droit de modifier tous moments les donn es consid r es n cessaires l amelioration du produit Technical data shown in this booklet are not binding Aermec S p A shall have the right to introduce at a...

Отзывы: