11.  MAINTENANCE

11.1. 

GENERAL NOTES

 

• 

Disconnect the power supply before 

cleaning the unit

• 

Disconnect the power supply when the 

air conditioner is off

• 

Do not pour water directly to the unit 

may cause an electrical shock

• 

Clean the cabinet with a soft, dry cloth or 

a cloth slightly dampened with water or 

detergent (do not use solvents)

11.2. 

CLEANING THE FRONT PANEL

Clean the dirty side of the panel with a cloth 

dampened with warm water. Do not immerse 

the panel in water, so as not to damage the 

electrical circuit.

11.3. 

CLEANING THE AIR FILTER

the air filter behind the intake grille must be 

washed at least once every two weeks.

Remove the air filter (as shown in the 
following figures):

• 

Open the air intake panel

• 

Remove the screws on the left and right 

sides (shown in the figure)

• 

Apply light force to the structure to 

remove the filter.

How to clean the filter:

1. To remove the air intake grille, grasp the tab 

of the filter and pull to unhook it.

2. When the filter cleaning LED light appears, 

it is better to operate this way; once the filter 

is removed, dust it with a vacuum cleaner. 

3. rinse the filter under running water, always 

facing up so as to wash away excess dust not 

captured by the vacuum cleaner.

4. Only if after these steps the filter is still 

dirty, fill a tub with lukewarm water and some 

non-aggressive cleanser and soak it for a few 

minutes. Next, dry it with a cloth.

5. Otherwise, have a specialised technician 

clean the filter.

NOTES:
Do not clean with water that is too hot.
Do not dry the flame.
Do not operate the air conditioner without the 
air filter.
Do not use brushes or tools drives.

11.4. 

CHECK BEFORE STARTING

• 

Check to make sure that the inlet and 

outlet are not obstructed by objects on 

both units, external and internal.

• 

Check to make sure the earthing cable is 

connected and not damaged.

• 

Check to make sure the air filter is clean.

• 

Make sure that the remote control 

batteries are exhausted.

• 

Make sure that the unit are not damaged 

and that they are securely fastened.

11.5. 

MAINTENANCE AFTER USE

• 

Disconnect the power supply.

• 

Clean the filter and the internal grilles.

• 

Clean the unit and remove any 

obstructions from the battery.

 WARNING:

• 

This

 

equipment is not intended for use by persons (including children) with reduced physical or sensory impairment, or lack of experience and knowledge, 

unless an individual is responsible for the supervision and safety of people above provide them with the necessary instructions and supervision.

• 

The device should not be used by children as a game.

• 

Instruct the customer on how to use the system by showing him/her the accompanying manual.

• 

Make sure that the power user falls within the tolerance (+ / -10%).

Air filter

Screws 

Содержание FK260

Страница 1: ...EN USE AND INSTALLATION MANUAL Aermec 16 01 5140901_01 FK260 FK360 Energy efficiency A 5140901_01...

Страница 2: ...NS FOR INSTALLATION OF THE UNIT 10 7 2 POSITIONING 10 7 3 MINIMUM TECHNICAL CLEARANCES 11 7 4 CONDENSATE DRAINAGE 11 7 5 ELECTRICAL WARNINGS 12 7 6 UNIT DIMENSIONS 12 8 WIRING DIAGRAMS 13 9 OPERATING...

Страница 3: ...laws All specifications are subject to change without prior notice Although every effort has been made to ensure precision Aermec does not assume any responsibility for any errors or omissions Dear c...

Страница 4: ...Y ONLY BE FOLLOWED BY SPECIALISED TECHNICIANS OR QUALIFIED PERSONNEL Make sure that other types of coolant do not contaminate the R32 The gas tank must be kept in a vertical position during filling Ap...

Страница 5: ...s Service these operations must only be carried out by Personnel with the specific technical skills Ensure that the power supply and the installed output are adequately scaled to supply the air condit...

Страница 6: ...cally check that the installation conditions of the unit have not been altered and have the system checked by a qualified engineer Do not remove the protection grilles Do not insert your hands or any...

Страница 7: ...remote control Control panel on the machine Compact unit with reduced dimensions Three possible functions Cooling Dehumidification Ventilation only Class A energy efficiency Contained sound emissions...

Страница 8: ...enser attachment diameter mm 7 7 Fan Type Axial Axial Air flow rate m3 h 800 1200 Sound pressure maximum dB A 56 58 Sound pressure medium dB A 54 56 Sound pressure minimum dB A 52 54 Sound power maxim...

Страница 9: ...9 Aermec 16 01 5140901_01 6 DESCRIPTION OF COMPONENTS Inner side Air filter Outer side...

Страница 10: ...the air delivery and intake sockets in the internal part so that air can circulate freely Ensure the installation complies with the minimum technical clearances specified in the installation diagram...

Страница 11: ...re starting up the unit Slide the frame of the unit from the base Install the drainage tub on the corner and fix it with two screws as shown in the figure Connect the drainage pipe NOT provided to the...

Страница 12: ...Ensure that the earthing cable is connected to the building s earthing connection system Ensure that a differential switch suitable for leaks to the ground is installed Do not connect the earth cable...

Страница 13: ...tilator PE W V U N AC L AP1 BN M BU YEGN BU YE RD Kompressor CN1 W V U YEGN 2 XT 1 berstrom ausl ser RD RD WARNUNG 15K 50K 20K CN3 RT1 RT2 RT3 WH BK Temp F hler Lufteintritt Temp F hler Register Temp...

Страница 14: ...e or generate noise Has a check for refrigerant leaks been performed Poor performance Is the thermal insulation sufficient It could cause condensate and dripping water Does the unit correctly drain th...

Страница 15: ...hese steps the filter is still dirty fill a tub with lukewarm water and some non aggressive cleanser and soak it for a few minutes Next dry it with a cloth 5 Otherwise have a specialised technician cl...

Страница 16: ...to select the fan speed 5 SWING button Press this button to select the fan mode from left to right 6 TIMER button Timer function for setting the time the unit is switched on or off Temp function to se...

Страница 17: ...d FAN Ventilation only mode the unit operates in ventilation mode In this case press the FAN button repeatedly to adjust the ventilation speed 3 button Function 1 Pressing or once will increase or red...

Страница 18: ...GRAMMED START UP FUNCTION When the unit is turned off pressed the Timer button to set the programmed start up function The T ON and H icons on the display will start to blink In 5 seconds press the bu...

Страница 19: ...careful not to invert the polarity Close the battery cover NOTE When batteries are replaced use new batteries of the recommended type Remove the batteries if the remote control is not used for extende...

Страница 20: ...room temperature We recommend that you do not keep the air jets direct instead set the unit to Swing mode Make sure the doors and windows are closed well Avoid opening the doors and windows of the roo...

Страница 21: ...ssor protection from overloading Contact specialised personnel or the Aermec Assistance Service L9 Power supply protection Contact specialised personnel or the Aermec Assistance Service H5 Module temp...

Страница 22: ...suggested by the producer of the material The unit must be installed in a space that respects the minimum allowed dimensions Please carefully observe the following table Verify that the maintenance ar...

Страница 23: ......

Страница 24: ...le droit de modifier tous moments les donn es consid r es n cessaires l amelioration du produit Technical data shown in this booklet are not binding Aermec S p A shall have the right to introduce at a...

Отзывы: