AERMEC FK260 Скачать руководство пользователя страница 16

16

Aermec. 16.01. 5140901_01

12.  CONTROL PANEL

5

1
7

2

3

4

8

SWING

HIGH
MID
LOW

COOL

DRY

FAN

AUTO

MODE

ON/OFF

FILTER

TIME/TEMP

FANSPEED

Alarm Function of the button:

1

ON/OFF button 

Press this button to turn the unit on or off.

2

MODE button

Press any button to activate one of the possible modes 

Press it multiple times until the desired mode is reached 

The selected mode will be marked with this symbol “   ”

every time it is pressed it will go to the next mode as follows:

COOL   DRY   FAN   

3

+/- button

Function 1

Pr or - once will increase or reduce the set temperature 

by 1°C. When + or - is pressed for 2 seconds 

the set temperature on the remote control changes quickly. Release the button once the desired temperature is reached.

Function 2

When setting the On or Off Timer, press + or - to adjust the time.

4

FAN button

Press this button to select the fan speed:

5

SWING button

Press this button to select the fan mode, from left to right.

6

TIMER button

Timer function for setting the time the unit is switched on or off.

Temp function to set the ambient temperature.

7

Infra-red signal receiver.

8

FILTER Button (Air Filter Cleaning Alarm Function)

Setting this function the unit will show automatically to the user when it’s necessary to clean the air filter.

Please remember that a regular cleaning of the air filter grants a better efficiency for air conditioner.

Push FILTER button to set this function. After 250 hours of operation the LED close to FILTER button will light and it will advise it is better 

to clean the air filter. 

The unit will continue to work properly also when the LED is on

. After cleaning the air filter it is necessary to push 

FILTER button to switch-off the LED and the function. Push the FILTER button again to set this function.

WARNING:

Wait 3 minutes before turning the unit back on after turning it off, or after a blackout.

USING THE UNIT

Содержание FK260

Страница 1: ...EN USE AND INSTALLATION MANUAL Aermec 16 01 5140901_01 FK260 FK360 Energy efficiency A 5140901_01...

Страница 2: ...NS FOR INSTALLATION OF THE UNIT 10 7 2 POSITIONING 10 7 3 MINIMUM TECHNICAL CLEARANCES 11 7 4 CONDENSATE DRAINAGE 11 7 5 ELECTRICAL WARNINGS 12 7 6 UNIT DIMENSIONS 12 8 WIRING DIAGRAMS 13 9 OPERATING...

Страница 3: ...laws All specifications are subject to change without prior notice Although every effort has been made to ensure precision Aermec does not assume any responsibility for any errors or omissions Dear c...

Страница 4: ...Y ONLY BE FOLLOWED BY SPECIALISED TECHNICIANS OR QUALIFIED PERSONNEL Make sure that other types of coolant do not contaminate the R32 The gas tank must be kept in a vertical position during filling Ap...

Страница 5: ...s Service these operations must only be carried out by Personnel with the specific technical skills Ensure that the power supply and the installed output are adequately scaled to supply the air condit...

Страница 6: ...cally check that the installation conditions of the unit have not been altered and have the system checked by a qualified engineer Do not remove the protection grilles Do not insert your hands or any...

Страница 7: ...remote control Control panel on the machine Compact unit with reduced dimensions Three possible functions Cooling Dehumidification Ventilation only Class A energy efficiency Contained sound emissions...

Страница 8: ...enser attachment diameter mm 7 7 Fan Type Axial Axial Air flow rate m3 h 800 1200 Sound pressure maximum dB A 56 58 Sound pressure medium dB A 54 56 Sound pressure minimum dB A 52 54 Sound power maxim...

Страница 9: ...9 Aermec 16 01 5140901_01 6 DESCRIPTION OF COMPONENTS Inner side Air filter Outer side...

Страница 10: ...the air delivery and intake sockets in the internal part so that air can circulate freely Ensure the installation complies with the minimum technical clearances specified in the installation diagram...

Страница 11: ...re starting up the unit Slide the frame of the unit from the base Install the drainage tub on the corner and fix it with two screws as shown in the figure Connect the drainage pipe NOT provided to the...

Страница 12: ...Ensure that the earthing cable is connected to the building s earthing connection system Ensure that a differential switch suitable for leaks to the ground is installed Do not connect the earth cable...

Страница 13: ...tilator PE W V U N AC L AP1 BN M BU YEGN BU YE RD Kompressor CN1 W V U YEGN 2 XT 1 berstrom ausl ser RD RD WARNUNG 15K 50K 20K CN3 RT1 RT2 RT3 WH BK Temp F hler Lufteintritt Temp F hler Register Temp...

Страница 14: ...e or generate noise Has a check for refrigerant leaks been performed Poor performance Is the thermal insulation sufficient It could cause condensate and dripping water Does the unit correctly drain th...

Страница 15: ...hese steps the filter is still dirty fill a tub with lukewarm water and some non aggressive cleanser and soak it for a few minutes Next dry it with a cloth 5 Otherwise have a specialised technician cl...

Страница 16: ...to select the fan speed 5 SWING button Press this button to select the fan mode from left to right 6 TIMER button Timer function for setting the time the unit is switched on or off Temp function to se...

Страница 17: ...d FAN Ventilation only mode the unit operates in ventilation mode In this case press the FAN button repeatedly to adjust the ventilation speed 3 button Function 1 Pressing or once will increase or red...

Страница 18: ...GRAMMED START UP FUNCTION When the unit is turned off pressed the Timer button to set the programmed start up function The T ON and H icons on the display will start to blink In 5 seconds press the bu...

Страница 19: ...careful not to invert the polarity Close the battery cover NOTE When batteries are replaced use new batteries of the recommended type Remove the batteries if the remote control is not used for extende...

Страница 20: ...room temperature We recommend that you do not keep the air jets direct instead set the unit to Swing mode Make sure the doors and windows are closed well Avoid opening the doors and windows of the roo...

Страница 21: ...ssor protection from overloading Contact specialised personnel or the Aermec Assistance Service L9 Power supply protection Contact specialised personnel or the Aermec Assistance Service H5 Module temp...

Страница 22: ...suggested by the producer of the material The unit must be installed in a space that respects the minimum allowed dimensions Please carefully observe the following table Verify that the maintenance ar...

Страница 23: ......

Страница 24: ...le droit de modifier tous moments les donn es consid r es n cessaires l amelioration du produit Technical data shown in this booklet are not binding Aermec S p A shall have the right to introduce at a...

Отзывы: