5.8 Automatic defrosting 

 

During air drying, ice may form at the evaporator. The volume of ice depends on the 
ambient conditions prevailing in the room to be dried. The air dryer is equipped with 
an automatic air-defroster. It ensures that, depending on the extent of ice formation, 
the appliance will be defrosted automatically according to the following principle: 

Ø

  A temperature sensor measures the condition existing in a critical area of the 

evaporator. 

Ø

  If a temperature of -1°C has been measured for at least 5 minutes, it passes a 

signal on to the defrost-system. During the defrost mode the fan keeps running, 
the compressor stands still. The ice on the evaporator is defrosted with the help 
of the ambient air. Depending upon ambient temperature this takes more or less 
time. After conclusion of the defrost mode (at the latest after 10 minutes) the 
dryer begins to work again in the normal dehumidifying mode.  

 

6. Operating conditions 

 

DH-condensation dryers are suitable for the effort in heated residential buildings, 
garages and storerooms. DH-condensation dryers work problem-free at the 
temperature range of +15 to +32°C and in the case of relative humidity from 40% to 
95% r.h. .  
The use in rooms with higher temperatures (> +32°C) leads to disadvantages at the 
compressor. The use in rooms with lower temperatures (< +15°C) is ineffective and 
can lead to icing. 
Also the storage of the dehumidifier at inadmissible temperature conditions can lead 
to damages / problems while immediate switch-on. Therefore, make possible short 
time for adaptation for the device before switch-on. 
 

ATTENTION: 

The appliance must not be used under the following conditions: 

Ø

 

in rooms of potentially explosive atmosphere 

Ø

 

in rooms of aggressive atmospheres, for example ammonia and wood acid 

Ø

 

In rooms with water which shows a pH-value outside of 7,0 to 7,4. 

Remark

: In  

The case of lower pH-value, corrosion occurs at all metals and damages occurs  
at mortar containing materials. In the case of higher pH-value, it comes to irritation 
of skin and eye mucous  membrane and extreme lime deposits. 

Ø

 

In rooms with salt or salty liquids. Salt content >1%  (also sole baths). 

Ø

 

In rooms of air treated with ozone 

Ø

 

in rooms featuring a high concentration of solvents 

Ø

 

in rooms of an extremely high ratio of dust

.

 

 
In the case of doubtful operating conditions it is recommended to contact the 
Technical Department of Messrs. AERIAL or a specialized dealer.  

 

Using a DH-air dryer under inadequate operating conditions will entail that the 
warranty becomes null and void. 
 
 
 
 
 
 

Содержание DH 18

Страница 1: ...page 1 of 14 Instruction manual _____________________________________ Dehumidifier DH 18 _____________________________________ Valid 01 2011...

Страница 2: ...5 6 5 2 Electrical connection 6 5 3 Putting into operation 6 7 5 4 Operation panel 7 5 5 Hygrostat control 7 8 5 6 Air flow 8 5 7 Condensate outlet 9 5 8 Automatic defrosting 10 6 Operating condition...

Страница 3: ...ble to send the device safe for guarantee repair In order to save space you open simply the adhesive tape with a knife and you fold the carton 2 Mode of functioning The DH air dryer is built particula...

Страница 4: ...rrespondingly and consider this operating manual precisely Using as directed The condensation dryers are intended for the drying of air with atmospheric pressure Risk by accessory Hoses for condensate...

Страница 5: ...e air filter must at least conduct 1 meter Before every local alternation of the device switch off the device at the on off switch pull the power plug from the socket and empty the water tank The air...

Страница 6: ...technical data of the appliance should be compared to the conditions prevailing in the room of installation 5 3 Putting into operation ATTENTION Before putting the air dryer into operation the instruc...

Страница 7: ...perating Voltage is connected 2 chart with neons Shows the approx Humidity of the ambient air in r h 3 neon green Dryer is in defrost mode fan is still working compressor does not work 4 neon red tank...

Страница 8: ...eter Please consider Humidity values of a minimum of 40 45 r h can be achieved with a condensation dryer An adsorption dryer is to be employed if lower values are required For this purpose ask your te...

Страница 9: ...f the tank and switches on automatically if the empty tank is placed back into the equipment Make sure that the carrying handle is folded correctly back into the tank Optionally a hose 12 mm can be in...

Страница 10: ...tive humidity from 40 to 95 r h The use in rooms with higher temperatures 32 C leads to disadvantages at the compressor The use in rooms with lower temperatures 15 C is ineffective and can lead to ici...

Страница 11: ...350 Watt 7 2 l 24h at 20 C 60 r h 300 Watt 8 Service Maintenance ATTENTION When performing any repair or maintenance the general safety rules and provisions must be adhered to In order to guarantee a...

Страница 12: ...5 4 Pos1 must light up Check the main cable an additional cable the socket and the main fuse The humidity value adjusted at the hygrostat is achieved The unit will start again after exceeding the adj...

Страница 13: ...AL air dryers we recommend get in touch with your supplier The producer AERIAL GmbH you reach under 0049 40 526879 0 or www aerial de 10 Disposal Please do not dispose this unit with the domestic wast...

Страница 14: ...afety of Machinery EN 50081 1 92 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN 50082 1 97 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN...

Отзывы: