7.Technical data 

 

Among other things, many different components which are installed in the 
condensation dryer decide on the capacity of the device. Since these components 
can never be completely identical, in accordance to DIN EN 810 the capacity may 
deviate up to 5% of specified capacity. 
 

Generell: 

Operational range: 

+15°C up to + 32°C   /   40% r.h. up to 95% r.h. 

Protection class:   

IP X0 

Voltage:  

 

230 V / 50 Hz 

 
Air volume: 

 

160 cbm/h 

Power consumption: 

max. 390 Watts 

Noise level: 

 

46 dB(A) in 1 mtr. distance 

refrigerant: 

 

R 134a 

capacity: 

 

18    l/24h at 30°C / 80% r.h. (390 Watt) 

         

 

 

10,5 l/24h at 27°C / 60% r.h. (350 Watt) 

 

 

 

7,2   l/24h at 20°C / 60% r.h. (300 Watt) 

 

8. Service & Maintenance 

 

ATTENTION 

When performing any repair or maintenance, the general safety rules and 
provisions must be adhered to! 

 

 
In order to guarantee a troublefree function of the dryer the device should be 
cleaned regularly. The following procedure is instead recommended: 

 

Ø

  Switch OFF the air dryer 

Ø

  Disconnect mains cable 

Ø

  Remove filter for cleaning. Filter can be washed under flowing water. 

Ø

  Visual inspection: check tank, hose connector and attached hose for blockage, 

if necessary change it 

Ø

  Clean case with moist cloth. Do not use aggressive Detergent 

Ø

  Insert new or cleaned filter 

Ø

  Put main plug into the sucket 

Ø

  Switch on dehumidifier. 

 

This cleaning is without fail regularly required! 

 
No other maintenance work is required for the air dryer. 
 
 
 
 
 
 
 
 
 
 

Содержание DH 18

Страница 1: ...page 1 of 14 Instruction manual _____________________________________ Dehumidifier DH 18 _____________________________________ Valid 01 2011...

Страница 2: ...5 6 5 2 Electrical connection 6 5 3 Putting into operation 6 7 5 4 Operation panel 7 5 5 Hygrostat control 7 8 5 6 Air flow 8 5 7 Condensate outlet 9 5 8 Automatic defrosting 10 6 Operating condition...

Страница 3: ...ble to send the device safe for guarantee repair In order to save space you open simply the adhesive tape with a knife and you fold the carton 2 Mode of functioning The DH air dryer is built particula...

Страница 4: ...rrespondingly and consider this operating manual precisely Using as directed The condensation dryers are intended for the drying of air with atmospheric pressure Risk by accessory Hoses for condensate...

Страница 5: ...e air filter must at least conduct 1 meter Before every local alternation of the device switch off the device at the on off switch pull the power plug from the socket and empty the water tank The air...

Страница 6: ...technical data of the appliance should be compared to the conditions prevailing in the room of installation 5 3 Putting into operation ATTENTION Before putting the air dryer into operation the instruc...

Страница 7: ...perating Voltage is connected 2 chart with neons Shows the approx Humidity of the ambient air in r h 3 neon green Dryer is in defrost mode fan is still working compressor does not work 4 neon red tank...

Страница 8: ...eter Please consider Humidity values of a minimum of 40 45 r h can be achieved with a condensation dryer An adsorption dryer is to be employed if lower values are required For this purpose ask your te...

Страница 9: ...f the tank and switches on automatically if the empty tank is placed back into the equipment Make sure that the carrying handle is folded correctly back into the tank Optionally a hose 12 mm can be in...

Страница 10: ...tive humidity from 40 to 95 r h The use in rooms with higher temperatures 32 C leads to disadvantages at the compressor The use in rooms with lower temperatures 15 C is ineffective and can lead to ici...

Страница 11: ...350 Watt 7 2 l 24h at 20 C 60 r h 300 Watt 8 Service Maintenance ATTENTION When performing any repair or maintenance the general safety rules and provisions must be adhered to In order to guarantee a...

Страница 12: ...5 4 Pos1 must light up Check the main cable an additional cable the socket and the main fuse The humidity value adjusted at the hygrostat is achieved The unit will start again after exceeding the adj...

Страница 13: ...AL air dryers we recommend get in touch with your supplier The producer AERIAL GmbH you reach under 0049 40 526879 0 or www aerial de 10 Disposal Please do not dispose this unit with the domestic wast...

Страница 14: ...afety of Machinery EN 50081 1 92 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN 50082 1 97 Electromagnetic Compatibility EMC Basic Specification Emitted Interference EN...

Отзывы: