Aercus Instruments™
- WeatherMaster
95 |
P a g e
Outdoor Sensors
:
Temperature range: -40°C – 60°C
Temperature resolution: 0.1°C
Temperature accuracy: ± 1°C
Humidity range: 10% - 99%
Humidity resolution: 1%
Humidity accuracy: ± 5% (between 20% and 90%)
Rain range: 0 – 9999 mm
Rain accuracy: ± 10%
Rain resolution: 0.3 mm (for volume < 1,000 mm)
1 mm (for volume ≥ 1,000 mm)
Wind Range: 0 – 50 m/s (0 ~ 100 mph)
Wind Accuracy: ± 1 m/s (speed < 5 m/s), ± 10% (speed ≥ 5 m/s)
UV-Index range: 0 - 15
Light range: 0 – 120 kLux
Light accuracy: ± 15%
Sensor reporting interval: 16 seconds
Note:
Out of range values will be displayed using “---”:
Power Consumption:
Console: 5V DC adaptor (included)
Indoor sensors: 2 x AA 1.5V Alkaline batteries (not included)
Outdoor sensors: 2 x AA 1.5V Alkaline batteries (not included), solar power
is used when available
Battery life: 12 months for console and 24 months for indoor sensor (use
Lithium batteries in cold weather climates)
Transmission Range: Up to 100m (line of sight)