Aercus Instruments™
- WeatherMaster
88 |
P a g e
Problem
Solution
Outdoor sensor array
does not communicate
to the display console.
The sensor array may have initiated properly
and the data is registered by the console as
invalid, and the console must be reset. Press
the reset button as described in Section
Installation.
With an open-ended paperclip, press the reset
button for 20 seconds to completely discharge
the voltage.
Take out the batteries and wait one minute,
while covering the solar panel to drain the
voltage.
Put batteries back in and resync with console by
powering down and up the console with the
sensor array about 10 feet away.
Bring the sensor array inside the house (you can
disconnect it from the rest of the sensors). The
LED next to the battery compartment will flash
every 16 seconds. If the LED is not flashing
every 16 seconds…
Replace the batteries in the outdoor sensor
array. If the batteries were recently replaced,
check the polarity. If the sensor is flashing every
16/48 (depending on model) seconds, proceed
to the next step.
There
may
be
a
temporary
loss
of