MODULEX EXT 321, 481, 641, 802, 962, 1123 BOILERS
Installation, Operation & Maintenance Manual
OMM-0087_0F
AERCO International, Inc.
•
100 Oritani Dr.
•
Blauvelt, NY 10913
Page
111
of
146
GF-143
Phone: 800-526-0288
07/13/15
5.10.1.3 A Second DHW Storage Tank
(Only After Function Selection)
Offers the possibility to use one of the heating zones for the preparation of a second DHW
storage tank.
EXPERT menu
⇒
Heating circuit I/II
⇒
HC FUNC. “03”
5.10.1.4 Temperature Setting For Second DHW Storage Tank
USER menu
⇒
Heating circuit / II
⇒
T- HW
5.10.1.5 Swimming Pool
Offers the possibility to use one of the heating zone for the heating of a swimming pool.
EXPERT menu
⇒
Heating circuit I/II
⇒
HC FUNC “02”
5.10.1.6 Swimming Pool Temperature Setting
(Only After Function Selection)
USER menu
⇒
Heating circuit I / II
⇒
T- POOL 1 / 2 / 3
5.10.1.7 Screed Dry Program (For Floor Heating Installation)
A program setting for drying the screed.
EXPERT menu
⇒
Installation
⇒
SCREED “01”
5.10.1.8 Temperature Setting For Screed Program
USER menu
⇒
Heating circuit I / II
5.10.1.9 Signal 0 – 10 V
Inlet of 0-10 V signal for slope control through an outer regulator (connect F15).
EXPERT menu
⇒
Solar/MF
⇒
FUNC. F15 “01”
5.10.1.10 Slope And Temperature Setting with 0 – 10 V Signal
See Table 5-7 for values.
EXPERT menu
⇒
Installation
⇒
TENS SLOPE (0 to 11)
EXPERT menu
⇒
Installation
⇒
SLOPE 11 – XX (freely settable)