background image

12

Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up 

to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified 

personnel. The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the 

regulations contained in this booklet.

1.PRECAUTIONS 

•  Make  sure  that  the  mains  supply  to  the  unit  is  disconnected  before  performing  any  installation,  service,  maintenance  or 

electrical work!

• The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in 

accordance with local rules and regulations.

• If any abnormality in operation is detected, disconnect the device from the mains supply and contact a qualified technician 

immediately.

• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user 

maintenance shall not be made by children without supervision.

• For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to 

provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).

• A wrong electrical wiring can cause damage to the fan and interfere with other electronic devices. 

2.TYPE

Controller for ventilation unit with 3 operation modes:

Mode 

A

 ==>  0-10V proportional fan control with wind sensor (Anemometer) and temperature block: main features of this mode 

are the setting of the wind speed at which fan rotation decreases to the minimum speed or stops, and of the 

temperature set at which the unit stops.

Mode 

B

 ==>  0-10V control proportional fan and  anemometer block (

DEFAULT)

:  main feature of this mode are the setting of 

the temperature at which the unit starts operating and of the wind speed at which the unit stops.

Mode 

C

 ==>  0-10V proportional fan control and destratification control with 2 temperature sensors: this mode allows the 

setting of the temperature at which the unit changes its operation mode from winter to summer (temperature and 

fan speed increase both proportionally).

2.1 HOW TO CHANGE THE MODE

Disconnect the controller from the main supply.
Keep the button            pressed and connect the controller to the main supply until the mode indication is shown on the display.
(

A

 =

 

010A

 or 

B

 =

 

010B

 or 

C

 =

 

010C

)

Release 

2.2 MODE CHECK

Switch the controller off and then on. On the display the following sequence is shown: 

AErA

/ -

L20

 / and then the set mode is displayed (

010A

 or 

010B

 or 

010C

).

Содержание CTRL-XWS

Страница 1: ...CTRL XWS Manuale Istruzioni 2 Instruction Manual 11 EN IT ...

Страница 2: ...ICATORI STATO FUNZIONAMENTO DEL SISTEMA 6 4 2 2 IMPOSTAZIONE TEMPERATURA DI VENTILAZIONE E BLOCCO ANEMOMETRICO 6 4 2 3 LETTURA IN DIRETTA DELLA DI VENTILAZIONE 6 4 2 4 COMANDO MANUALE 7 4 2 5 CONFIGURAZIONE DATI COSTANTI 7 4 3 BLOCCO ANEMOMETRICO 7 4 4 MEMORIA DELLE TEMPERATURE REGISTRATE 7 4 5 RESET DEL SISTEMA 7 5 CONTROLLO VENTILAZIONE PROPORZIONALE 0 10V E CONTROLLO DESTRATIFICAZIONE CON 2 SON...

Страница 3: ...ne conformemente alle regole di installazione un interruttore onnipolare che consenta la disconnessione completa nelle condizioni della categoria di sovratensione III distanza dei contatti uguale o superiore a 3mm Il collegamento elettrico non corretto può recare danno anche al ventilatore e interferire con altri dispositivi elettronici 2 TIPOLOGIA Regolatore per il controllo delle unità di ventil...

Страница 4: ...zione 3 2 1 INDICATORI STATO FUNZIONAMENTO DEL SISTEMA 3 2 2 IMPOSTAZIONE VELOCITÀ DEL VENTO E BLOCCO TEMPERATURA Premere il led sul tasto lampeggia sul display compare il messaggio SET 3 0v Impostazione della velocità del vento m s km h mph per spegnere il ventilatore o ridurre la velocità al minimo Premere oppure per modificare il valore Premere il led sul tasto lampeggia sul dispaly compare il ...

Страница 5: ...e Min anemometro A v Hi Valore allarme Max anemometro D SE r isteresi relè allarme anemometro D SE t isteresi on off azione blocco temperatura t Int tempo di integrazione 0 10V ImP numero di impulsi al giro Circ circonferenza della pala Unit unita di misura 0 m s 1 mph 2 km h Star velocità minima di partenza Premere per due volte compare l impostazione del blocco temperatura SET C 10 0 Premere opp...

Страница 6: ...D MIN MAX 4 2 2 IMPOSTAZIONE TEMPERATURA DI VENTILAZIONE E BLOCCO ANEMOMETRICO Premere il led sul tasto lampeggia sul display compare il messaggio SET C 10 Impostazione della temperatura di partenza ventole Premere oppure per aumentare o diminuire Premere il led sul tasto lampeggia sul dispaly compare il messaggio SET 3 0v Impostazione del blocco anemometrico Facoltativo Premere oppure per aumenta...

Страница 7: ... d SE r isteresi on off azione blocco vento t Int tempo di integrazione 0 10V ImP numero di impulsi al giro Circ circonferenza della pala Unit unita di misura 0 m s 1 mph 2 km h Star velocita minima di partenza Premere per due volte compare l impostazione della velocità limite del vento SET 3 0v Premere oppure per aumentare o diminuire Attivando nelle CONF la funzione ANEM 1 e collegando il sensor...

Страница 8: ... ALLARME 18 GND 0 USCITA SEGNALE 19 10V 10Vcc USCITA SEGNALE 5 1 COLLEGAMENTO ELETTRICO 5 2 FUNZIONALITÀ Indicatore velocità di ventilazione 5 2 1 INDICATORI STATO FUNZIONAMENTO DEL SISTEMA DIFFERENTIAL SPEED MIN MAX 5 2 2 IMPOSTAZIONE TEMPERATURA DI CAMBIO MODALITÀ DI FUNZIONAMENTO Premere il led sul tasto lampeggia sul display compare il messaggio SET C 10 Impostazione della temperatura per camb...

Страница 9: ...biente i led dei due tasti si spengono 5 2 4 MODALITÀ INVERNO DESTRATIFICAZIONE A 2 SONDE La regolazione della ventilazione varia al variare delle temperature rilevate dalle sonde basandosi sulla differenza di temperatura tra la sonda al soffitto e quella al suolo Al crescere della differenza fra le due temperature la velocità aumenta in modo proporzionale alla banda impostata P B VI Data una diff...

Страница 10: ...o allo stato originale 5 2 7 CONFIGURAZIONE DATI COSTANTI Premere contemporaneamente e per circa 5 secondi Sul display compaiono quattro linee e successivamente il messaggio CONF Premere per scorrere il menu di configurazioni Parametri P r o b Cor 1 correzione sonda temperatura soffitto Cor 2 correzione sonda temperatura terra SCAL C F scala di lettura Air SP Lo limite minima velocità SP Hi limite...

Страница 11: ...LITIES 15 4 2 1 INDICATORS OF THE SYSTEM STATUS 15 4 2 2 SETTING OF VENTILATION TEMPERATURE AND ANEMOMETER BLOCK 15 4 2 3 READING OF VENTILATION 15 4 2 4 MANUAL CONTROL 16 4 2 5 SETTING OF THE CONSTANT DATA 16 4 3 ANEMOMETER BLOCK 16 4 4 MEMORY OF THE REGISTERED TEMPERATURES 16 4 5 SYSTEM RESET 16 5 0 10V PROPORTIONAL FAN CONTROL AND DESTRATIFICATION CONTROL WITH 2 TEMPERATURE PROBES Mode C 17 5 1...

Страница 12: ...mnipolar switch should be incorporated in the fixed wiring in accordance with the wiring regulations to provide a full disconnection under overvoltage category III conditions contact opening distance equal to or greater than 3mm A wrong electrical wiring can cause damage to the fan and interfere with other electronic devices 2 TYPE Controller for ventilation unit with 3 operation modes Mode A 0 10...

Страница 13: ... 3 2 1 INDICATORS OF THE SYSTEM STATUS 3 2 2 SETTING OF WIND SPEED AND TEMPERATURE BLOCK Press the led on the button flashes the message SET 3 0v is displayed Setting of the wind speed m s km h mph to stop the unit or to reduce its speed to minimum Press or to change the value Press the led on the button flashes the message SET C 10 is displayed Setting of the temperature block C F Mandatory Press...

Страница 14: ...mometer alarm D SE r anemometer alarm relays hysteresis D SE t on off temperature block hysteresis t Int 0 10V integration time ImP number of pulses per revolution Circ blade circumference Unit unit of measure 0 m s 1 mph 2 km h Star minimum starting speed Press twice the button the temperature block setting SET C 10 0 is displayed Connect the temperature probe mandatory when the detected temperat...

Страница 15: ...ENTIAL SPEED MIN MAX 4 2 2 SETTING OF TEMPERATURE AND ANEMOMETER BLOCK Press the led on the button flashes the message SET C 10 is displayed Setting of the temperature at which the fan starts Press or to increase decrease Press the led on the button flashes the message SET 3 0v is displayed Setting of the anemometer block Optional Press or to increase decrease Press to exit the led on the button s...

Страница 16: ...activation wind block d SE r on off anemometer block hysteresis t Int 0 10V integration time ImP number of pulses per revolution Circ blade circumference Unit unit of measure 0 m s 1 mph 2 km h Star minimum starting speed Press twice the anemometer block setting SET 3 0v is displayed Press or to increase decrease By activating in CONF the function ANEM 1 and by connecting the anemometer when the w...

Страница 17: ...N SIGNAL OUTPUT 5 1 WIRING DIAGRAM 5 2 FUNCTIONALITIES Ventilation speed indicator 5 2 1 INDICATORS OF THE SYSTEM STATUS DIFFERENTIAL SPEED MIN MAX 5 2 2 SETTING OF TEMPERATURE TO CHANGE THE OPERATION MODE Press the led on the button flashes the message SET C 10 is displayed Setting of the temperature at which the operation mode changes between INV winter and EST summer Press or to change the mode...

Страница 18: ...the temperature difference between the ceiling probe and the ground probe When the difference between the two temperatures increases the speed increases proportionally to the set band P B VI Given a difference in temperature the variation of the ventilation speed will be GREATER if the band is narrow and LESS if the band is wide 5 2 3 OPERATION IN SUMMER MODE 1 TEMPERATURE PROBE When the temperatu...

Страница 19: ...tting will return to the default 5 2 7 SETTING OF THE CONSTANT DATA Press contemporaneously and for about 5 seconds Four lines are shown on the display and then the message CONF is displayed Press to scroll the setting menu Parameters P r o b Cor 1 ceiling temperature probe correction Cor 2 ground temperature probe correction SCAL C F Celsius or Fahrenheit degree Air SP Lo of minimum speed SP Hi o...

Страница 20: ...9930981 REA BS 528635 Tel 39 030 674681 Fax 39 030 6872149 www aerauliqa com info aerauliqa it Aerauliqa srl si riserva il diritto di modificare apportare migliorie ai prodotti e o alle istruzioni di questo manuale in qualsiasi momento e senza preavviso Aerauliqa srl reserves the right to modify make improvements to products and or this instruction manual at any time and without prior notice ...

Отзывы: