Parameter 43: Lux Threshold

 
Size: 2 Byte, Default Value: 250

Setting

Description

0 - 10000

Lux Threshold 0 = disabled

Parameter 44: UV Threshold

 
Size: 1 Byte, Default Value: 1

Setting

Description

0 - 11

UV Threshold 0 = disabled

Parameter 45: Threshold Check Time

Set threshold check time in seconds if the threshold is enabled via Parameter 40. 

 

Size: 2 Byte, Default Value: 240

Setting

Description

1 - 65535

Set threshold check time in seconds when USB powered

60 - 65535

Set theshould check time in secons when Battery powered

Parameter 46: Low Temperature Report

Enable/Disable alarm report for low temperature 

 

Size: 1 Byte, Default Value: 1

Setting

Description

0

Disable

1

Enable

Parameter 48: Sensor Limit Control

Содержание AEOEZWA024

Страница 1: ...icallypairthesensorifyourZ Wave hubsupportsthis Important safety information Please read this manual carefully Failure to follow the recommendations in this manual may be dangerous or may violate the law The manufacturer importer distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material Use this equ...

Страница 2: ...n AeotecMultiSensor7wasdevelopedtodetectambientvaluesandmovementandtotransmitthemwithZ WavePlus Itispoweredby Aeotec sGen7technology YoucanfindoutmoreaboutMultiSensor7byfollowingthatlink Prepare for Installation Reset Please read the user manual before installing the product In order to include add a Z Wave device to a network it must be in factory default state Please make sure to reset the devic...

Страница 3: ...controller ForaUSBpoweredinstallation actsasarepeaterwhenpairedonUSBpower 1 RemovethebatterycoverbyslidingtheUnlockbuttonLEFT thenpullthecoveroff 2 InserttheMicroUSBoftheprovidedUSBcableintoyoursensor sMicroUSBport 3 InsertthelargerendoftheUSBcableintoacomputerorany5VadapterwhichwillimmediatelypoweryourMultiSensor7 4 MakesuretoseattheBatteryCoverbackontotheMultiSensor7andlockitinbyslidingtheUnlock...

Страница 4: ...hiumbatteriesorientatedaccordingtothediagramwithinyoursensor Tryinsertingthebatteriesflatratherthanatanangle Note MultiSensor7canbepoweredbyasingleCR123A doesn tmatterwhichport thoughbatterieswillrequirechangingmorefrequently half theexpectedbatterylife WARNING NotcompatiblewithrechargeableCR123Abatteries 3 6V 3 MakesuretoseattheBatteryCoverbackontotheMultiSensor7andlockitinbyslidingtheUnlockbutto...

Страница 5: ...all your TriSensor with the Back Mount Plate 1 You can affix the Back Mount Arm by Double Sided Tape or using the provided KA2 5ƒ 20 mm screws Tips We suggest you choose the second method using screws to affix the Back Mount Arm which would be more stable 2 After you have completed the affixing of Back Mount Arm you will need to lock TriSensor to the Back Mount Arm by screwing TriSensor in ...

Страница 6: ...wave eu backend make php lang en sku AEOEZWA024 cert ZC12 20120147 6 37 3 The Back Mount Arm may be locked at various angles by turning the Friction Lock clockwise and counter clockwise to respectively tighten or loosen the angle of the arm You can rotate the Friction Lock to change the measurement area of sensor ...

Страница 7: ... network This process is called Inclusion Devices can also be removed from a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion 1 Open the Cover 2 Insert the batter...

Страница 8: ...ill send a wakeup report to your Z Wave Controller to take in any queued z wave commands waiting in your controller Press and hold 5 9 seconds Solid Orange Long Wakeup Mode LED will remain solid Orange upon release of its button for 5 minutes maximum or until told to sleep by user or z wave controller This will allow you to easily configure this device while the sensor is used with battery power a...

Страница 9: ...s significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification The controller can then empty the mailbox Therefore the device needs to be configured with the desired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configura...

Страница 10: ...or network installation if things dont work as expected 1 Make sure a device is in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll FLIRS devices 6 M...

Страница 11: ...Basic Set When the current light lux is under or over the threshold set by Param19 9 5 Basic Set When the current UV is over or under the threshold set by Param20 10 5 Basic Set When the current UV is under or over the threshold set by Param21 11 5 Sensor Multilevel Report When sensors above over limit or below under limit Configuration Parameters Z Wave products are supposed to work out of the bo...

Страница 12: ...ll be reset This setting value must always be less than timeout configuration 0 disable1 3600 timeout set in seconds Size 2 Byte Default Value 30 Setting Description 30 3600 timeout set in seconds Parameter 3 Motion Untrigger Time Timeout configuration set in second for motion sensor to send no trigger status Size 2 Byte Default Value 240 Setting Description 30 3600 timeout set in seconds Paramete...

Страница 13: ...etting Description 0 disable vibration 1 254 timeout set in minutes to reset vibration status 255 timeout set in minutes to reset vibration status Parameter 7 Vibration Intensity Reports Used to enable disable vibration intensity reports If set to 1 vibration intensity will be sent to gateway when triggered Size 1 Byte Default Value 0 Setting Description 0 Disable 1 Enable Parameter 9 Wakeup CC Ti...

Страница 14: ...ce 1 Send BASIC_SET 0x00 when motion is triggered Send BASIC_SET 0xFF when motion is untriggered 2 Send BASIC_SET 0xFF when motion is triggered Nothing when motion untriggered 3 Send BASIC_SET 0x00 when motion is triggered Nothing when motion untriggered 4 Send BASIC_SET 0x00 when motion is untriggered Nothing when motion triggered 5 Send BASIC_SET 0xFF when motion is untriggered Nothing when moti...

Страница 15: ...00 to associated devices through group5 Size 1 Byte Default Value 60 Setting Description 0 100 Set threshold of humidity Parameter 15 Under Humidity Group Threshold Group6 Set threshold of humidity If measure humidity this value send BASIC_SET 0x00 to associated devices through group6 Size 1 Byte Default Value 40 Setting Description 0 100 Set threshold of humidity Parameter 16 Over Heat Group Thre...

Страница 16: ...ated devices If measured light lux this value send BASIC_SET 0x00 to associated devices Size 2 Byte Default Value 2000 Setting Description 0 30000 Set threshold of Light Lux Parameter 19 Under Light Group Threshold Group8 Set threshold of Light Lux If measured light lux this value send BASIC_SET 0x00 to associated devices Size 2 Byte Default Value 100 Setting Description 0 30000 Set threshold of L...

Страница 17: ...0 Setting Description 10 90 Configure low battery report threshold Parameter 40 Threshold Check Enable Disable Enable Disable threshold reporting check time can be adjusted by Param45 Size 1 Byte Default Value 0 Setting Description 0 disable all threshold reports 1 enable all threshold reports Parameter 41 Temperature Threshold Threshold Value 0 1 Scale is determined by Param64 Size 1 Byte Default...

Страница 18: ...ault Value 1 Setting Description 0 11 UV Threshold 0 disabled Parameter 45 Threshold Check Time Set threshold check time in seconds if the threshold is enabled via Parameter 40 Size 2 Byte Default Value 240 Setting Description 1 65535 Set threshold check time in seconds when USB powered 60 65535 Set theshould check time in secons when Battery powered Parameter 46 Low Temperature Report Enable Disa...

Страница 19: ...perature lower level 32 Humidity lower level 64 Lux lower level 128 UV lower level Parameter 49 Temperature Upper Limit Set upper limit level for temperature set in scale of 0 1 Scale is determined by Param64 If Current measurement Upper Limit then report sensor Size 2 Byte Default Value 280 Setting Description 400 1000 Set upper limit level for temperature Parameter 50 Temperature Lower Limit Set...

Страница 20: ...ture recover limit set in scale of 0 1 Parameter 52 Humidity Upper Limit Set humidity upper limit level Size 1 Byte Default Value 60 Setting Description 0 100 Set humidity upper limit level Parameter 53 Humidity Lower Limit Set humidity lower limit level Size 1 Byte Default Value 40 Setting Description 0 100 Set humidity lower limit level Parameter 54 Humidity Recover Limit Set humidity recover li...

Страница 21: ...Param 51 Size 1 Byte Default Value 100 Setting Description 1 255 Set lux recover limit level Parameter 58 UV Upper Limit Set UV upper limit level Size 1 Byte Default Value 8 Setting Description 1 11 Set UV upper limit level Parameter 59 UV Lower Limit Set UV lower limit level Size 1 Byte Default Value 4 Setting Description 1 11 Set UV lower limit level Parameter 60 UV Recover Limit Set UV recover ...

Страница 22: ...escription 0 within limit 1 Temperature upper level 2 Humidity upper level 4 Lux upper level 8 UV upper level 16 Temperature lower level 32 Humidity lower level 64 Lux lower level 128 UV lower level Parameter 64 Temperature Scale Set the scale for temperature when reports Size 1 Byte Default Value 0 Setting Description 0 Celsius 1 Fahrenheit Parameter 81 LED Activity Allow user to enable disable L...

Страница 23: ...e Parameter 82 Motion Sensor Report Indicator If LED is enabled by Param81 allow user to change the report color of motion sensor Size 1 Byte Default Value 3 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 83 Temperature Sensor Report Indicator If LED is enabled by Param81 allow user to change the report color of temperature sensor Size...

Страница 24: ...ackend make php lang en sku AEOEZWA024 cert ZC12 20120147 24 37 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 84 Humidity Sensor Report Indicator If LED is enabled by Param81 allow user to change the report color of humidity sensor Size 1 Byte Default Value 0 ...

Страница 25: ... eu backend make php lang en sku AEOEZWA024 cert ZC12 20120147 25 37 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 85 Lux Sensor Report Indicator If LED is enabled by Param81 allow user to change the report color of Lux sensor Size 1 Byte Default Value 0 ...

Страница 26: ...OEZWA024 cert ZC12 20120147 26 37 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 86 UV Sensor Report Indicator If LED is enabled by Param81 allow user to change the report color of UV sensor 0 Disabled1 Red2 Blue3 Green4 Pink5 Cyan6 Purple7 Orange8 Yellow9 White Size 1 Byte Default Value 0 ...

Страница 27: ...ckend make php lang en sku AEOEZWA024 cert ZC12 20120147 27 37 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 87 Vibration Sensor Report Indicator If LED is enabled by Param81 allow user to change the report color of vibration sensor Size 1 Byte Default Value 2 ...

Страница 28: ...ave eu backend make php lang en sku AEOEZWA024 cert ZC12 20120147 28 37 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 88 Battery Report Indicator If LED is enabled by Param81 allow user to change the report color of battery Size 1 Byte Default Value 0 ...

Страница 29: ...wave eu backend make php lang en sku AEOEZWA024 cert ZC12 20120147 29 37 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 89 Wakeup Report Indicator If LED is enabled by Param81 allow user to change the report color of wakeup Size 1 Byte Default Value 8 ...

Страница 30: ... lang en sku AEOEZWA024 cert ZC12 20120147 30 37 Setting Description 0 Disable 1 Red 2 Blue 3 Green 4 Pink 5 Cyan 6 Purple 7 Orange 8 Yellow 9 White Parameter 90 Communication Indicator If LED is enabled by Param81 allow user to change indicator color when receiving communication from gateway or other devices Size 1 Byte Default Value 0 ...

Страница 31: ...hite Parameter 101 Automatic Report Checklist 1 Checklist 1 for automatic timed report When the corresponding item is selected it will be checked when timeout setting by Param111 Size 1 Byte Default Value 241 Setting Description 1 Battery 16 UV 32 Temperature 64 Humidity 128 Lux Parameter 102 Automatic Report Checklist 2 Checklist 2 for automatic timed report When the corresponding item is selecte...

Страница 32: ...l be checked when timeout setting by Param113 Size 1 Byte Default Value 0 Setting Description 1 Battery 16 UV 32 Temperature 64 Humidity 128 LUX Parameter 111 Automatic Checklist 1 Interval Time Interval time set in seconds to check the checklist1s items Multilevel Sensor Report will be sent when timeout Size 2 Byte Default Value 3600 Setting Description 30 65535 Interval time set in seconds Param...

Страница 33: ... 30 65535 Interval time set in seconds Parameter 201 Temperature Offset Value Can add or minus this setting value to calibrate temperature when checked Scale is defined by Param64 e g Value 15 means 1 5C or 1 5F Size 2 Byte Default Value 0 Setting Description 200 200 Temperature Offset Value Parameter 202 Humidity Offset Value Can add or minus this setting value to calibrate humidity when checked ...

Страница 34: ...12 20120147 https manual zwave eu backend make php lang en sku AEOEZWA024 cert ZC12 20120147 34 37 Parameter 204 UV Offset Value Can add or minus this setting value to calibrate UV when checked Size 1 Byte Default Value 0 Setting Description 10 10 Offset Value range 10 10 Technical Data ...

Страница 35: ...ware Platform ZGM130 EAN 1220000016873 IP Class IP 20 Voltage 3V Battery Type 2 CR123A Device Type Notification Sensor Network Operation Always On Slave Z Wave Version 7 12 2 Certification ID ZC12 20120147 Z Wave Product Id 0x0371 0x0002 0x0018 Firmware Updatable Updatable by Consumer by RF Color White Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes Application...

Страница 36: ...y 2 Sensor Binary V2 Sensor Multilevel V11 Supervision Transport Service V2 Version V3 Wake Up V2 Zwaveplus Info V2 Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors...

Страница 37: ...controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions c 2022 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwave eu The template ...

Отзывы: